What are the instrumentation requirements for measuring the isotopic composition of net ecosystem exchange of CO2 using eddy covariance methods?
نویسندگان
چکیده
Better quantification of isotope ratios of atmosphere-ecosystem exchange of CO2 could substantially improve our ability to probe underlying physiological and ecological mechanisms controlling ecosystem carbon exchange, but the ability to make long-term continuous measurements of isotope ratios of exchange fluxes has been limited by measurement difficulties. In particular, direct eddy covariance methods have not yet been used for measuring the isotopic composition of ecosystem fluxes. In this article, we explore the feasibility of such measurements by (a) proposing a general criterion for judging whether a sensor's performance is sufficient for making such measurements (the criterion is met when the contribution of sensor error to the flux measurement error is comparable to or less than the contribution of meteorological noise inherently associated with turbulence flux measurements); (b) using data-based numerical simulations to quantify the level of sensor precision and stability required to meet this criterion for making direct eddy covariance measurements of the 13C/12C ratio of CO2 fluxes above a specific ecosystem (a mid-latitude temperate forest in central Massachusetts, USA); (c) testing whether the performance of a new sensor-a prototype pulsed quantum cascade laser (QCL) based isotope-ratio absorption spectrometer (and plausible improvements thereon)-is sufficient for meeting the criterion in this ecosystem. We found that the error contribution from a prototype sensor (approximately 0.2 per thousand, 1 SD of 10 s integrations) to total isoflux measurement error was comparable to (1.5 to 2x) the irreducible 'meteorological' noise inherently associated with turbulent flux measurements above this ecosystem (daytime measurement error SD of approximately 60% of flux versus meteorological noise of 30-40% for instantaneous half-hour fluxes). Our analysis also shows that plausible instrument improvements (increase of sensor precision to approximately 0.1 per thousand, 1 SD of 10 s integrations, and increased sensor stability during the half-hour needed to integrate eddy covariance measurements) should decrease the contribution of sensor error to the point where it is less than the contribution from meteorological noise. This suggests that new sensors using QCL-based isotope ratio absorption spectroscopy should make continuous long-term observations of the isotopic composition of CO2 fluxes via eddy covariance methods feasible.
منابع مشابه
Critical evaluation of micrometeorological methods for measuring ecosystem–atmosphere isotopic exchange of CO2
Isotopic net ecosystem exchange (isofluxes, or flux densities of CO2) can be combined with standard eddy covariance methods to partition net ecosystem exchange of carbon dioxide (F) into its component one-way fluxes, photosynthesis and respiration. At present, the approaches used to estimate isotopic fluxes are labor-intensive and dependent on several assumptions. To assess the relative utility...
متن کاملGross primary production, ecosystem respiration and net ecosystem exchange in Asian rice paddy: an eddy covariance-based approach
Carbon dioxide (CO2) exchange between the terrestrial ecosystems and the atmosphere is one of the major processes affecting atmospheric CO2 concentration. In various ecosystems in the world long-term observations of CO2 exchange have been made for assessing the role of terrestrial ecosystems in the present-day global CO2 budget and to predict its changes in the future climatic scenario. The edd...
متن کاملFeasibility of 13CO2 eddy covariance flux measurements using pulsed quantum cascade tunable infrared laser differential absorb
Better quantification of atmosphere-ecosystem exchange of the isotopologues of CO2 could substantially improve our ability to probe underlying physiological and ecological mechanisms controlling ecosystem carbon exchange, but the ability to make long-term continuous measurements of the isotopic composition of exchange fluxes has been limited by measurement difficulties. Quantum cascade (QC) las...
متن کاملComparison of eddy covariance and chamber-based methods for measuring CO2 flux in a temperate mixed forest.
Two methods, eddy covariance and chamber-based measurements, were employed to measure the net ecosystem CO(2) exchange in a mature temperate mixed forest in 2003. The eddy covariance system was used as a reference, which was compared with the chamber-based method. Based on chamber fluxes, the ecosystem had a gross primary production of 1490 g C m(-2) year(-1), 90% of which was released as efflu...
متن کاملContinuous measurements of net CO2 exchange by vegetation and soils in a suburban landscape
[1] In a suburban neighborhood of Minneapolis–Saint Paul, Minnesota, USA, we simultaneously measured net CO2 exchange of trees using sap flow and leaf gas exchange measurements, net CO2 exchange of a turfgrass lawn using eddy covariance from a portable tower, and total surface-atmosphere CO2 fluxes (FC) using an eddy covariance system on a tall tower. Two years of continuous measurements showed...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Isotopes in environmental and health studies
دوره 42 2 شماره
صفحات -
تاریخ انتشار 2006