Mid-term comparative follow-up after aortic valve replacement with Carpentier-Edwards and Pericarbon pericardial prostheses.
نویسندگان
چکیده
BACKGROUND The first generation of pericardial valves had a high rate of premature deterioration. The aim of this study was to compare the outcome after aortic valve replacement with second generation pericardial prostheses (Pericarbon and Carpentier-Edwards). METHODS AND RESULTS Between 1987 and 1994, 162 patients underwent aortic valve replacement with either a Pericarbon (n=81, 69+/-11 years) or a Carpentier-Edwards (n=81, 70+/-11 years) pericardial prosthesis. Mean follow-up was 4.4+/-2.7 years for Pericarbon and 4.8+/-2.4 years for Carpentier-Edwards valves (P=0. 27), giving a total follow-up of 745 patient-years. Thirty-day mortality and 5-year actuarial survival were, respectively, 6.2% and 63.2+/-5.7% in the Pericarbon group and 6.2% and 63.5+/-5.6% in the Carpentier-Edwards group. At 8 years, freedom from (and linearized rates per patient-year) thromboembolism, structural failure, and all valve-related events were, respectively, 91.8+/-3.6% (1.4%), 76. 9+/-8.7% (2.5%), and 58.4+/-9.3% (5.6%) in the Pericarbon group and 94.4+/-2.7% (1%), 100% (0%, P<0.01), and 88.8+/-3.7% (2%, P<0.05) in the Carpentier-Edwards group. There were 9 (11.1%) Pericarbon structural failures related predominantly to severe calcification and stenosis. The actual reoperation rate was 7.4% (1.6% per patient-year) in the Pericarbon group for fibrocalcific degeneration (n=3), periprosthetic leak (n=1), endocarditis (n=1), and aortic dissection (n=1). There was neither structural valve failure nor valve reoperation in the Carpentier-Edwards group. Echocardiographic review of 70 patients from 85 survivors (82.3%) found 4 additional Pericarbon valves with signs of early structural failure but no Carpentier-Edwards valve with such changes. CONCLUSIONS Eight years after aortic valve replacement, Pericarbon pericardial prostheses compared unfavorably with Carpentier-Edwards pericardial prostheses, with a high incidence of structural valve failure and reoperation.
منابع مشابه
Comparable long-term results for porcine and pericardial prostheses after isolated aortic valve replacement
OBJECTIVES Outcome of aortic valve replacement may be influenced by the choice of bioprosthesis. Pericardial heart valves are described to have a favourable haemodynamic profile compared with porcine valves, although the clinical notability of this finding is still controversially debated. Herein, we compared the long-term results of two commonly implanted bioprosthesis at a single centre. ME...
متن کاملVery long-term outcomes of the Carpentier-Edwards Perimount valve in aortic position.
BACKGROUND The Carpentier-Edwards Perimount pericardial bioprosthesis (Edwards Lifesciences, Irvine, CA) has demonstrated good long-term outcomes, but its durability remains unclear depending on age at implantation. We report our 20-year experience with the Perimount valve implanted in the aortic position, with particular attention to the probability and time to reoperation required due to biop...
متن کاملTHERAPY AND PREVENTION VALVE REPLACEMENT A prospective evaluation of the Bjbrk-Shiley, Hancock, and Carpentier-Edwards heart valve prostheses
From 1975 to 1979, 540 patients undergoing valve replacement were entered into a randomized trial and received either a Bjdrk-Shiley (273 patients) or a porcine heterograft prosthesis (initially a Hancock valve [107 patients] and later a Carpentier-Edwards prosthesis [ 160 patients]). Two hundred and sixty-two patients required mitral valve replacement, 210 required aortic valve replacement, 60...
متن کاملHancock, and Carpentier-Edwards heart valve prostheses
From 1975 to 1979, 540 patients undergoing valve replacement were entered into a randomized trial and received either a Bjdrk-Shiley (273 patients) or a porcine heterograft prosthesis (initially a Hancock valve [107 patients] and later a Carpentier-Edwards prosthesis [ 160 patients]). Two hundred and sixty-two patients required mitral valve replacement, 210 required aortic valve replacement, 60...
متن کاملDurability of pericardial versus porcine aortic valves.
OBJECTIVES This study compares the long-term performance of the Carpentier-Edwards (CE) porcine bioprosthesis and the CE pericardial bioprosthesis for aortic valve replacement (AVR). BACKGROUND With new bioprostheses on the horizon, there is renewed interest in how the long-term durability of current pericardial bioprostheses compares with the traditional porcine bioprosthesis. METHODS We r...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 100 19 Suppl شماره
صفحات -