The repeatability and criterion related validity of the 20 m multistage fitness test as a predictor of maximal oxygen uptake in active young men.

نویسندگان

  • S-M Cooper
  • J S Baker
  • R J Tong
  • E Roberts
  • M Hanford
چکیده

OBJECTIVE To investigate the repeatability and criterion related validity of the 20 m multistage fitness test (MFT) for predicting maximal oxygen uptake (Vo(2max)) in active young men. METHODS Data were gathered from two phases using 30 subjects (x+/-s; age = 21.8+/-3.6 years, mass = 76.9+/-10.7 kg, stature = 1.76+/-0.05 m). MFT repeatability was investigated in phase 1 where 21 subjects performed the test twice. The MFT criterion validity to predict Vo(2max) was investigated in phase 2 where 30 subjects performed a continuous incremental laboratory test to volitional exhaustion to determine Vo(2max) and the MFT. RESULTS Phase 1 showed non-significant bias between the two applications of the MFT (x(diff)+/-s(diff) = -0.4+/-1.4 ml kg(-1) min(-1); t = -1.37, p = 0.190) with 95% limits of agreement (LoA) +/-2.7 ml kg(-1) min(-1) and heteroscedasticity 0.223 (p = 0.330). Log transformation of these data reduced heteroscedasticity to 0.056 (p = 0.808) with bias -0.007+/-0.025 (t = -1.35, p = 0.190) and LoA+/-0.049. Antilogs gave a mean bias on the ratio scale of 0.993 and random error (ratio limits) x/divided by 1.050. Phase 2 showed that the MFT significantly underpredicted Vo(2max) (x(diff)+/-s(diff) = 1.8+/-3.2 ml kg(-1) min(-1); t = 3.10, p = 0.004). LoA were +/-6.3 ml kg(-1) min(-1) and heteroscedasticity 0.084 (p = 0.658). Log transformation reduced heteroscedasticity to -0.045 (p = 0.814) with LoA+/-0.110. The significant systematic bias was not eliminated (x(diff)+/-s(diff) = 0.033+/-0.056; t = 3.20, p = 0.003). Antilogs gave a mean bias of 1.034 with random error x/divided by 1.116. CONCLUSIONS These findings lend support to previous investigations of the MFT by identifying that in the population assessed it provides results that are repeatable but it routinely underestimates Vo(2max) when compared to laboratory determinations. Unlike previous findings, however, these results show that when applying an arguably more appropriate analysis method, the MFT does not provide valid predictions of Vo(2max).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Review article

The main purpose of the present meta-analysis was to examine the criterion-related validity of the 20-m shuttle run test for estimating cardiorespiratory fitness. Relevant studies were searched from twelve electronic databases up to December 2014, as well as from several alternative modes of searching. The Hunter-Schmidt’s psychometric meta-analysis approach was conducted to estimate the popula...

متن کامل

Comparison of two aerobic field tests in young tennis players.

This study compares the maximal responses of a new aerobic tennis field test, the NAVTEN to a known aerobic field test, often used with young tennis players, that is, the continuous multistage 20-m shuttle run test (20-m SRT). The NAVTEN is an intermittent (1-minute/1-minute) multistage test with side-to-side displacements and ball hitting. Ten young elite tennis players aged 12.9 ± 0.3 (mean ±...

متن کامل

Compaison the effect of resistance exercise with active and passive rest on aerobic and anaerobic fitness in soccer players

The aim of this study was to Compare the effect of resistance training with active and passive rest on aerobic and anaerobic fitness in soccer players. For this purpose 16 players of Foolad Mobarakeh Sepahan club, accidentally were divided into rest and active group (Height 177.78±6.68 cm, Weight 64.88±7.97 kg, age 18.22±0.83 years ,and percent fat 20.47±1.8) and rest passive group(Height 17...

متن کامل

Comparison of maximal fat oxidation and Fatmax between active and inactive elderly men

Background&Purpose: The aim of this study was to compare of maximal fat oxidation and the exercise intensity that elicit maximal fat oxidation (Fatmax) between active and inactive elderly men. Methodology: 10 healthy elderly men that had regular exercise (at least 10 past years, ,VO2max 44.6±4.5 ml.kg.min) and 10 healthy elderly men that hadn’t any regular exercise (at least 10 past years, VO2m...

متن کامل

Combat Readiness Test: Design and Validation in the Iranian Military

Background and Aim: Physical fitness is a major contributor to combat readiness, and current military tests do not measure it appropriately. The purpose of this study was to design a combat readiness test that could reliably and consistently determine the level of physical fitness distinctly required prior to deployment into the battlefield. Methods: The subjects of this study were military per...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British journal of sports medicine

دوره 39 4  شماره 

صفحات  -

تاریخ انتشار 2005