The Abbott TDx evaluated for T-uptake
نویسنده
چکیده
The Abbott TDx therapeutic drug-monitoring system is based on fluorescence polarization. Polarization fluoroimmunoassay makes use of competitive binding, measuring the tracer binding directly, without the need for separation procedures. The attraction of non-radioactive polarization fluoroimmunoassay for the determination of T-uptake is that there is no radiation hazard and that the homogeneous method is very convenient.
منابع مشابه
Thyroid-function testing with the TDx: interference from endogenous fluorophore.
One agent used by ophthalmologists to aid in funduscopic examinations is sodium fluorescein (“Funduscein,” Cooper Vision). We recently received a patient’s specimen for measurement of thyroxin (T4) and T3-uptake, drawn one day after she had been examined by an ophthalmologist. Owing to the high background fluorescence (62 580 arb.units) and low background polarization (24 mPol), no results were...
متن کاملAn evaluation of a fluorescence polarization immunoassay of thyroxin and thyroxin-uptake.
We evaluated the fluorescence polarization immunoassay for total thyroxin (T4) and thyroxin-uptake (T-U) in the Abbott "TDx" Analyzer. Between-assay precision was good when we did once-fortnightly calibration and assayed samples in singleton. Measured T4 concentration was decreased in hemolyzed samples with obvious red coloration and undetectable in severely hemolyzed samples. The T-U assay was...
متن کاملComparative analysis of two rapid automated methods and a semiautomated version of the urease method for determining aminoglycoside concentrations in serum.
The Syva EMIT Autolab 6000 and the Abbott TDX automated methods for measuring serum aminoglycoside concentrations were compared with each other and with a new semiautomated version of the urease technique. Each was evaluated for accuracy, reproducibility, cost, and ease of use. All three methods gave satisfactory results, although the Abbott TDX was the most accurate. Both automated methods gav...
متن کاملAbbott TDx, Dade Stratus, and Du Pont aca automated digoxin immunoassays compared with a reference radioimmunoassay method.
Automated digoxin immunoassays with the Abbott TDx, Dade Stratus, and Du Pont aca were evaluated against an RIA similar to the Centers for Disease Control Candidate Reference Method. All three automated methods correlated poorly with the reference method. Particularly disconcerting were the falsely increased values (up to 0.6 micrograms/L) obtained by the Stratus for blank specimens. We discuss...
متن کاملAnomalous serum thyroxin measurements with the Abbott TDx procedure.
We describe a patient whose serum gave consistently low results for thyroxin as measured with the Abbott TDx but normal results by radioimmunoassay. Further clinical and laboratory studies did not support the low TDx results. Anti-thyroxin antibodies did not explain the discordant results, and we found no evidence of heterophilic antibodies in the patient's serum. We were unable to identify the...