Assessment of Diesse Ves-matic automated system for measuring erythrocyte sedimentation rate.
نویسندگان
چکیده
Measurement of the erythrocyte sedimentation rate (ESR) using a closed tube system reduces the biohazard risk to laboratory staff. The Diesse Ves-matic system offers manual or vacuum collection of blood into plastic tubes, automated mixing of the sample, and automated reading of the end point after 20 minutes of sedimentation. This system was compared with the 1977 Westergren ESR method of the International Council for Standardization in Haematology (ICSH) and with the 1988 ICSH undiluted ESR method. Manually collected Ves-matic samples showed good agreement with ICSH values, although there was a tendency to false low results at low ESR values which may represent dilution of plasma protein with excess citrate. Vacuum collected Ves-matic samples also showed good agreement with ICSH values, although there was a tendency to false high results which may reflect a change in the blood: citrate ratio caused by loss of anticoagulant diluent or vacuum from plastic tubes during storage. The Diesse Ves-matic system incorporates several improvements over previous technology and offers a safer, quicker, and more standardised ESR.
منابع مشابه
Evaluation of the Ves-Matic Cube 200 erythrocyte sedimentation method: comparison with Westergren-based methods.
The erythrocyte sedimentation rate (ESR) is still a widely used parameter for acute phase inflammation. Recently, new methods based on direct undiluted measurement of ESR in a standard EDTA tube have been developed. We evaluated the analytic performance of one of these new methods, the Ves-Matic Cube 200 (Diesse Diagnostica Senese, Siena, Italy), and compared it with several established Westerg...
متن کاملInternal Quality Control for Erythrocyte Sedimentation Rate Using Patient Blood Sample
The erythrocyte sedimentation rate (ESR) test continues to be used as an important tool in many laboratories; either manually or as automated method. When automation is applied in clinical laboratories, it is imperative that reliable methods for calibration and appropriate control materials are available for monitoring the accuracy and precision of the results generated. But when the commercial...
متن کاملEvaluation of Ves-Matic Cube 200--an automated system for the measurement of the erythrocyte sedimentation rate.
Ves-Matic Cube 200 is fully automated analyzer that performs erythrocyte sedimentation rate (ESR) measurement using the standard ethylenediaminetetraacetic acid blood sample tube, thus markedly reducing the analytical time and avoiding the need for an extra blood sample. The aim of this study was to assess the automatic Ves-Matic Cube 200 system for the measurement of ESR in comparison with the...
متن کاملValidation of the Diesse Mini-Ves erythrocyte sedimentation rate (ESR) analyzer using the Westergren ESR method in patients with systemic inflammatory conditions.
The Diesse Mini-Ves (DMV) erythrocyte sedimentation rate (ESR) analyzer was designed to improve efficiency in determining the ESR. We compared the Westergren ESR method with the 4-sample DMV ESR analyzer for performance and clinical correlation. This prospective observational study, conducted at a 450-bed tertiary medical center, evaluated 291 paired samples from subjects with various systemic ...
متن کاملIs erythrocyte sedimentation rate a useful inflammatory marker independently of the hematocrit? Comparison results with plasma viscosity.
Plasma viscosity (PV) and erythrocyte sedimentation rate (ESR) are tests which can be used as inflammation and tissue injury markers [2, 11]. ESR usage is more extended than PV in clinical laboratories. However ESR may be haematocrit (Ht) dependent and is related with red blood cell (RBC) rheological properties [1], whereas RBC are not involved in PV. We aimed to evaluate retrospectively the im...