Bone remodeling, particle disease and individual susceptibility to periprosthetic osteolysis.
نویسندگان
چکیده
Bone remodeling is a tightly coupled process consisting of repetitive cycles of bone resorption and formation. Both processes are governed by mechanical signals, which operate in conjunction with local and systemic factors in a discrete anatomic structure designated a basic multicellular unit (BMU). The microenvironment around total joint arthroplasty is a dynamic and complex milieu influenced by the chemical and physical stimuli associated with servicing the prosthesis. A key factor limiting the longevity of the prosthesis is polyethylene wear, which induces particle disease, and this may lead to increased and prolonged activity of BMUs resulting in periprosthetic osteolysis. Several pathways regulating BMU function have been reported in the past, including RANKL/RANK/OPG/TRAF6, TNF-alpha/TNFR/TRAF1, and IL-6/CD126/JAK/STAT. Moreover, the expression and functional activity of all these molecules can be affected by variations in their genes. These may explain the differences in severity of bone defects or prosthetic failure between patients with similar wear rates and the same prosthesis. Simultaneously, this data strongly support the theory of individual susceptibility to prosthetic failure.
منابع مشابه
Inflammatory Periprosthetic Bone Loss
Total hip arthroplasty [THA] is one of the most successful and effective procedures developed for the treatment of pain and lack of mobility associated with end-stage arthritis such as osteoarthritis and rheumatoid arthritis. Approximately 1.5 million joint arthroplastic operations are performed annually worldwide. THA, although considered an excellent surgical procedure, can be complicated by ...
متن کاملParticle Disease: A Current Review of the Biological Mechanisms in Periprosthetic Osteolysis After Hip Arthroplasty
BACKGROUND Inflammatory responses to wear debris cause osteolysis that leads to aseptic prosthesis loosening and hip arthroplasty failure. Although osteolysis is usually associated with aseptic loosening, it is rarely seen around stable implants. Aseptic implant loosening is a simple radiologic phenomenon, but a complex immunological process. Particulate debris produced by implants most commonl...
متن کاملBone-Implant Interface Biology ―― Foreign Body Reaction and Periprosthetic Osteolysis in Artificial Hip Joints――
Aseptic loosening and periprosthetic osteolysis are major problems in artificial hip joint surgery,for which a solution has yet to be found. Biological host response to wear debris combined with cyclic mechanical loading onto the bone bed around hip prosthetic implants has been considered as mechanism responsible for implant-mediated periprosthetic osteolysis. Any type of artificial joint glidi...
متن کاملExtracellular Matrix Degradation and Tissue Remodeling in Periprosthetic Loosening and Osteolysis: Focus on Matrix Metalloproteinases, Their Endogenous Tissue Inhibitors, and the Proteasome
The leading complication of total joint replacement is periprosthetic osteolysis, which often results in aseptic loosening of the implant, leading to revision surgery. Extracellular matrix degradation and connective tissue remodeling around implants have been considered as major biological events in the periprosthetic loosening. Critical mediators of wear particle-induced inflammatory osteolysi...
متن کاملParticle disease. A comprehensive theory of periprosthetic osteolysis: a review.
Aseptic loosening and osteolysis are considered the main long-term problems of hip arthroplasty. Pathogenesis of periprosthetic osteolysis is multifactorial, and both the biological and mechanical factors seem to play an important role. Bearing surfaces continuously generate excessive amounts of micron and submicron particles provoking an adverse inflammatory response of periprosthetic connecti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physiological research
دوره 57 3 شماره
صفحات -
تاریخ انتشار 2008