Totally endoscopic atrial septal defect repair with robotic assistance.
نویسندگان
چکیده
BACKGROUND The development of minimally invasive cardiac surgery has been characterized by the performance of increasingly complex operations through progressively smaller incisions. Computer (robotic) enhancement has emerged as a potential facilitator of these procedures, initially by providing enhanced endoscopic camera control and, more recently, by allowing the manipulation of surgical instruments through limited thoracic incisions. This report describes the next step in this progression, namely the performance of an atrial septal defect (ASD) repair entirely through thoracoscopic port incisions. This represents the first U.S. application of robotic technology for totally endoscopic open-heart surgery. MATERIALS AND METHODS A 33-year-old woman with a secundum atrial septal defect underwent totally endoscopic repair through four port incisions by means of the Da Vinci (Intuitive Surgical, Mountain View, CA) robotic surgical system. Cardiopulmonary bypass was achieved peripherally (femoral Estech endoaortic balloon cannula; femoral and right internal jugular venous Bio-medicus cannulae). The myocardium was protected with antegrade cold blood cardioplegia delivered through the distal port of the arterial cannula. After port insertion, the entire operation, including pericardiotomy, bicaval occlusion, atriotomy, atrial septopexy, and atrial closure, was performed by computer-aided control of a camera and two instrument arms manipulated by a surgeon seated 15 feet away. The fourth port was used for suction and suture passage by the patient-side assistant. The aortic cross-clamp time was 43 minutes, and the postoperative transesophageal echocardiogram demonstrated normal ventricular function and the absence of interatrial shunting. The patient was extubated on the night of surgery, was ambulatory within 15 hours, and was discharged on the morning of postoperative day 3, 63 hours after the procedure. At 30-day follow-up, the patient was well and without complaints, and transthoracic echocardiogram confirmed the continued absence of interatrial shunting. CONCLUSIONS Computer-aided robotic surgical technology can be used to perform open-heart procedures with a totally endoscopic approach. The benefits of this approach may include decreased perioperative pain, decreased recovery times, and improved cosmesis and patient acceptance. Clinical trials currently in progress will demonstrate whether this technology will be of reproducible value in the management of patients with intracardiac disease on a larger scale.
منابع مشابه
Robotic-assisted endoscopic atrial septal defect closure: analysis of 115 cases in a single center.
OBJECTIVE To summarize the experience with the application of robotic technique in totally endoscopic atrial septal defect closure in a single center. METHODS Between January 2007 and September 2011, 115 patients with the diagnosis of secundum type atrial septal defects underwent robotic atrial septal defect repair with the assistance of da Vinci surgical system. The patients had a median age...
متن کاملTotally Endoscopic Cardiac Surgery for Atrial Septal Defect Repair on Beating Heart Without Robotic Assistance in 25 Patients
OBJECTIVE The aim of the study was to investigate the effectivity and safety of totally endoscopic cardiac surgery without robotic assistance for atrial septal defect (ASD) closure on beating hearts. METHODS Twenty-five patients (adults/children: 15/10) underwent ASD closure using nonrobotically assisted totally endoscopic approach on beating heart. Three 5-mm trocars and one 12-mm trocar wer...
متن کاملExperience on the way to totally endoscopic atrial septal defect repair.
BACKGROUND Remote-access perfusion and robotics have enabled totally endoscopic closure of atrial septal defect (ASD) and patent foramen ovale (PFO). We report on a stepwise approach to a totally endoscopic procedure. METHODS Seventeen patients (median age, 39 years; range, 21-55 years) underwent limited-access ASD or PFO closure. As a preparative step, the operation was carried out through m...
متن کاملTotally robotic repair of atrioventricular septal defect in the adult
BACKGROUND Atrioventricular septal defect (AVSD) accounts for up to 3 % of congenital cardiac defects, which is routinely repaired via median sternotomy. Minimally invasive approach such as endoscopic or robotic assisted repair for AVSD has not been reported in the literature. With the experience with robotic mitral valve surgery and congenital defect repair, we initiated robotic AVSD repair in...
متن کاملTotal endoscopic robotic atrial septal defect repair in a patient with dextrocardia and situs inversus totalis.
Situs inversus with mirror-image of the heart is a rare condition. The present report describes a case of a patient with dextrocardia with situs inversus who had atrial septal defect with multiple holes in the fossa ovalis. The patient underwent total endoscopic atrial septal defect repair using the da Vinci surgical system. This procedure was achieved safely with good clinical and excellent co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The heart surgery forum
دوره 5 3 شماره
صفحات -
تاریخ انتشار 2002