Microworm optode sensors limit particle diffusion to enable in vivo measurements.

نویسندگان

  • Gozde Ozaydin-Ince
  • J Matthew Dubach
  • Karen K Gleason
  • Heather A Clark
چکیده

There have been a variety of nanoparticles created for in vivo uses ranging from gene and drug delivery to tumor imaging and physiological monitoring. The use of nanoparticles to measure physiological conditions while being fluorescently addressed through the skin provides an ideal method toward minimally invasive health monitoring. Here we create unique particles that have all the necessary physical characteristics to serve as in vivo reporters, but with minimized diffusion from the point of injection. These particles, called microworms, have a cylindrical shape coated with a biocompatible porous membrane that possesses a large surface-area-to-volume ratio while maintaining a large hydrodynamic radius. We use these microworms to create fluorescent sodium sensors for use as in vivo sodium concentration detectors after subcutaneous injection. However, the microworm concept has the potential to extend to the immobilization of other types of polymers for continuous physiological detection or delivery of molecules.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Phosphate-selective fluorescent sensing microspheres based on uranyl salophene ionophores.

Optical dihydrogen phosphate-selective sensors that function on the basis of bulk optode principles and are based on two different uranyl salophene ionophores are reported here for the first time. The influence of the optode composition and measuring conditions such as sample pH on the optode response are characterized, along with sensor selectivity and long-term stability. Three plasticizers o...

متن کامل

Design and Evaluation of a Mercury (II) Optode Based on Immobilization of 5, 6 Di methyl -1- (4 methyl benzyl) -2- para tolyl-1H-benzimidazole (DMBPTBI) on a Triacetylcellulose Membrane and Determination in Various Samples

The characterization of an optical sensor membrane is described for the determination of Hg2+ ions based on the immobilization of 5, 6 Di methyl -1- ( 4 methyl benzyl) -2- para tolyl-1H-benzimidazole (DMBPTBI) on a triacetylcellulose membrane. The membrane responds to mercury ions by changing color reversibly from orange to red in universal buffer solution at pH 2. Under optimum conditions, the...

متن کامل

Reduction of image artifacts induced by change in the optode coupling in time-resolved diffuse optical tomography.

Tomographic images of the optical properties can be reconstructed using inversion algorithms for diffuse optical tomography (DOT); however, changes in the optode coupling that occurs while obtaining an object's measurements may often lead to the presence of artifacts in the reconstructed images. To reduce the number of artifacts induced by optode coupling, previous studies have introduced (unkn...

متن کامل

ارزیابی دقت دو دستگاه آپکس یاب الکترونیکی (Electronic Apex Locator) از نسل چهارم در تعیین طول کانال (In-vivo)

Background and Aim: Determining correct working length in root canal therapy is of great importance in successful treatment. The purpose of this study was to compare the accuracy of two electronic apex locators of fourth generation, Raypex4 and Apit7, in determining working length in vivo. Materials and Methods: In this test evaluation study performed at Dental School of Tehran University, a to...

متن کامل

A novel technique for the precise measurement of CO2 production rate in small aquatic organisms as validated on aeshnid dragonfly nymphs.

The present study describes and validates a novel yet simple system for simultaneous in vivo measurements of rates of aquatic CO2 production (ṀCO2 ) and oxygen consumption (ṀO2 ), thus allowing the calculation of respiratory exchange ratios (RER). Diffusion of CO2 from the aquatic phase into a gas phase, across a hollow fibre membrane, enabled aquatic ṀCO2  measurements with a high-precision in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Proceedings of the National Academy of Sciences of the United States of America

دوره 108 7  شماره 

صفحات  -

تاریخ انتشار 2011