CARDIOVASCULAR MEDICINE Comprehensive cardiac rehabilitation programme for implantable cardioverter-defibrillator patients: a randomised controlled trial

نویسنده

  • C J Garratt
چکیده

Objective: To investigate the effects of a 12 week comprehensive cardiac rehabilitation (CCR) programme on patients who have undergone implantation of an implantable cardioverter-defibrillator (ICD). Design: Sixteen patients with ICDs (14 (88%) male, mean (SD) age 58 (10) years, range 34–74 years) were randomised to either attend an individually tailored CCR programme or receive usual care. They then changed to the alternative regimen for a further 12 weeks. Exercise capacity was assessed using a treadmill exercise test at baseline, after usual care, after CCR and 12 weeks after CCR to assess maintenance effects. Hospital anxiety and depression (HAD) scores were recorded at each stage. Results: Exercise times (min:s; mean (SD)) increased by 16% from a baseline mean of 9:55 (2:33) to 11:11 (2:17) following attendance at CCR (95% confidence interval (CI) 0:34 to 1:58; p = 0.001). This improvement was maintained 12 weeks after attendance at CCR, at 11:20 (2:17) (p = 1.00). HAD scores for anxiety and depression decreased during CCR from a baseline of 13.4 (3.6) to 8.1 (3.6), 95% CI 3.5 to 7.0 (p < 0.001) and 9.9 (3.4) to 6.7 (2.9), 95% CI 1.9 to 4.4 (p = 0.002), respectively. These improvements were maintained at 12 weeks after CCR. No ventricular arrhythmias or ICD discharges occurred during the exercise components of the CCR. The total number of ventricular arrhythmias and ICD discharges was similar 12 weeks before, during, and 12 weeks after CCR. Conclusions: CCR appears to be safe for patients with ICDs. It can improve exercising ability and lower the levels of psychological distress. A larger multicentre study is recommended to confirm these findings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implantable cardioverter defibrillator specific rehabilitation improves health cost outcomes: Findings from the COPE-ICD randomized controlled trial.

OBJECTIVE The Copenhagen Outpatient ProgrammE - implantable cardioverter defibrillator (COPE-ICD) trial included patients with implantable cardioverter defibrillators in a randomized controlled trial of rehabilitation. After 6-12 months significant differences were found in favour of the rehabilitation group for exercise capacity, general and mental health. The aim of this paper is to explore t...

متن کامل

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

Combined resynchronisation and implantable defibrillator therapy in left ventricular dysfunction: Bayesian network meta-analysis of randomised controlled trials.

OBJECTIVE To review the evidence base from randomised controlled trials of combined cardiac resynchronisation therapy and implantable cardioverter defibrillator therapy in left ventricular impairment and symptomatic heart failure. DESIGN Bayesian network meta-analysis. DATA SOURCES Medline, Embase, and Cochrane databases up to June 2006. REVIEW METHODS Two reviewers independently assessed...

متن کامل

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...