Evaluation of the Zeiss retinal vessel analyser.

نویسندگان

  • K Polak
  • G Dorner
  • B Kiss
  • E Polska
  • O Findl
  • G Rainer
  • H G Eichler
  • L Schmetterer
چکیده

AIM To investigate the reproducibility and sensitivity of the Zeiss retinal vessel analyser, a new method for the online determination of retinal vessel diameters in healthy subjects. METHODS Two model drugs were administered, a peripheral vasoconstrictor (the alpha receptor agonist phenylephrine) and a peripheral vasodilator (the nitric oxide donor sodium nitroprusside) in stepwise increasing doses. Nine healthy young subjects were studied in a placebo controlled double masked three way crossover design. Subjects received intravenous infusions of either placebo or stepwise increasing doses of phenylephrine (0.5, 1, or 2 microg/kg/min) or sodium nitroprusside (0.5, 1, or 2 microg/kg/min). Retinal vessel diameters were measured with the new Zeiss retinal vessel analyser. Retinal leucocyte velocity, flow, and density were measured with the blue field entoptic technique. The reproducibility of measurements was assessed with coefficients of variation and intraclass correlation coefficients. RESULTS Placebo and phenylephrine did not influence retinal haemodynamics, although the alpha receptor antagonist significantly increased blood pressure. Sodium nitroprusside induced a significant increase in retinal venous and arterial diameters (p<0.001 each), leucocyte density (p=0.001), and leucocyte flow (p=0.024) despite lowering blood pressure to a significant degree. For venous and arterial vessel size measurements short term coefficients of variation were 1.3% and 2.6% and intraclass correlation coefficients were 0.98 and 0.96, respectively. The sensitivity was between 3% and 5% for retinal veins and 5% and 7% for retinal arteries. CONCLUSIONS These data indicate that the Zeiss retinal vessel analyser is an accurate system for the assessment of retinal diameters in healthy subjects. In addition, nitric oxide appears to have a strong influence on retinal vascular tone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reduced response of retinal vessel diameters to flicker stimulation in patients with diabetes.

BACKGROUND/AIM Stimulation of the retina with flickering light increases retinal arterial and venous diameters in animals and humans, indicating a tight coupling between neural activity and blood flow. The aim of the present study was to investigate whether this response is altered in patients with insulin dependent diabetes mellitus. METHODS 26 patients with diabetes mellitus with no or mild...

متن کامل

Extracting Vessel Centerlines From Retinal Images Using Topographical Properties and Directional Filters

In this paper we consider the problem of blood vessel segmentation in retinal images. After enhancing the retinal image we use green channel of images for segmentation as it provides better discrimination between vessels and background. We consider the negative of retinal green channel image as a topographical surface and extract ridge points on this surface. The points with this property are l...

متن کامل

Hyperglycemia affects flicker-induced vasodilation in the retina of healthy subjects

Flickering light stimulation of retinal photoreceptors induces retinal vessel dilation in humans. In the present study the effect of high blood glucose levels on this neuro-vascular mechanism was investigated in 12 healthy young male subjects. Blood glucose levels were consecutively increased during 30 min to 100, 200 and 300 mg/dl and kept at the respective level for the following 30 min using...

متن کامل

Validation of the automatic image analyser to assess retinal vessel calibre (ALTAIR): a prospective study protocol

INTRODUCTION The fundus examination is a non-invasive evaluation of the microcirculation of the retina. The aim of the present study is to develop and validate (reliability and validity) the ALTAIR software platform (Automatic image analyser to assess retinal vessel calibre) in order to analyse its utility in different clinical environments. METHODS AND ANALYSIS A cross-sectional study in the...

متن کامل

Effects of dopamine on human retinal vessel diameter and its modulation during flicker stimulation.

We performed a randomized, subject-blinded, placebo and time-controlled, two-way crossover study in 12 healthy male subjects. Placebo or dopamine was administered on two separate study days. After saline infusion, dopamine hydrochloride was infused in three consecutive doses (5, 10, and 15 microg x kg(-1) x min(-1)). Plasma levels of dopamine were determined at each perfusion step. Arterial and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 84 11  شماره 

صفحات  -

تاریخ انتشار 2000