Analysis of fluid in capsules implanted into dog brain.
نویسندگان
چکیده
Perforated capsules were implanted aseptically into the brain parenchyma of dogs. The tissue and fluid formed within these intracerebral capsules (BC) were analysed for their ions and protein content. The results were compared with those for other perforated capsules implanted simultaneously into the subcutaneous tissue and muscle, respectively (denoted SC and MC). The following results were obtained: 1) In BC and MC, the Na/K ratio was different from that of the respective control tissues (cerebral parenchyma and temporal muscle) but similar to that of both the tissue in SC and control connective tissue. The water content of the three different capsular tissues was almost identical, but in each case different from that of the respective control tissues. 2) The Na/K ratio, Cl and protein content, and electrophoretic patterns of the three capsular fluids were similar to one another, and to serum. However, all (including BC fluid) were different in composition from the CSF (cerebrospinal fluid). 3) Investigations of the effect of time lapse after capsular implantation showed that the Na and K content was generally constant over the observed period, except that the K value was high in the initial few weeks. 4) Based on the results obtained, and on our data for pressure reequilibration in BC, the nature of the fluid compartment in BC is discussed. It is considered to represent an extension of the narrow space existing physiologically between the blood capillary wall and glial membrane, and not to be part of the true interstitial fluid compartment. 5) The barrier existing between the blood and brain parenchyma may be regarded not as a single membrane but as two membranes of dissimilar nature.
منابع مشابه
Interstitial fluid pressure. 3. Its effect on resistance to tissue fluid mobility.
The resistance to fluid mobility in the interstitial fluid spaces has been measured between perforated catheters inserted into the subcutaneous abdominal tissues of the dog and between perforated capsules implanted in the tissues 1 month previously. When the pressures in the catheters or perforated capsules were less than atmospheric pressure, the resistance to fluid movement was almost infinit...
متن کاملInterstitial Fluid Pressure: III. Its Effect on Resistance to Tissue Fluid Mobility
The resistance to fluid mobility in the interstitial fluid spaces has been measured between perforated catheters inserted into the subcutaneous abdominal tissues of the dog and between perforated capsules implanted in the tissues 1 month previously. When the pressures in the catheters or perforated capsules were less than atmospheric pressure, the resistance to fluid movement was almost infinit...
متن کاملA concept of negative interstitial pressure based on pressures in implanted perforated capsules.
• Interstitial pressure has usually been measured by inserting a very small needle into a tissue and then determining the minimum pressure required to make fluid flow from the needle into the tissue." Unfortunately, even when extremely small needles are used for this purpose, such as 25 to 30 gauge, the external diameter of the needle is still some 300 to 500 times as large as the widths of the...
متن کاملInterstitial fluid pressure. V. Negative pressure in the lungs.
Interstitial fluid pressures in the lung were estimated in 39 dogs from pressure measurements made in implanted perforated capsules. Special operative procedures were used to minimize operative trauma of the lungs and infection and inflammation in and around the implanted capsules. In 86X of the preparations, the x-ray findings indicated little remaining inflammation and edema around the capsul...
متن کاملTreatment of ophidism-induced bilateral canine cataract by extracapsular lens extraction and intraocular lens implantation
The aim of this study was to report a new cause of cataract, namely snake bite induced cataract in a dog. A 3-year-old male mongrel dog was referred to our clinic for the assessment of cataract in both eyes. The dog was bitten by a snake nearly 4 months ago. A 40 dioptre acrylic lens with 13 mm haptics was implanted into the lens capsule. In the left eye, posterior synechia was detected in the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Japanese journal of physiology
دوره 24 1 شماره
صفحات -
تاریخ انتشار 1974