Myocardial lipid content in Fabry disease: a combined 1H-MR spectroscopy and MR imaging study at 3 Tesla

نویسندگان

  • B Petritsch
  • H Köstler
  • A M Weng
  • M Horn
  • T Gassenmaier
  • A S Kunz
  • F Weidemann
  • C Wanner
  • T A Bley
  • M Beer
چکیده

BACKGROUND Fabry disease is characterized by a progressive deposition of sphingolipids in different organ systems, whereby cardiac involvement leads to death. We hypothesize that lysosomal storage of sphingolipids in the heart as occurring in Fabry disease does not reflect in higher cardiac lipid concentrations detectable by 1H magnetic resonance spectroscopy (MRS) at 3 Tesla. METHODS Myocardial lipid content was quantified in vivo by 1H-MRS in 30 patients (12 male, 18 female; 18 patients treated with enzyme replacement therapy) with genetically proven Fabry disease and in 30 healthy controls. The study protocol combined 1H-MRS with cardiac cine imaging and LGE MRI in a single examination. RESULTS Myocardial lipid content was not significantly elevated in Fabry disease (p = 0.225). Left ventricular (LV) mass was significantly higher in patients suffering from Fabry disease compared to controls (p = 0.019). Comparison of patients without signs of myocardial fibrosis in MRI (LGE negative; n = 12) to patients with signs of fibrosis (LGE positive; n = 18) revealed similar myocardial lipid content in both groups (p > 0.05), while the latter showed a trend towards elevated LV mass (p = 0.076). CONCLUSIONS This study demonstrates the potential of lipid metabolic investigation embedded in a comprehensive examination of cardiac morphology and function in Fabry disease. There was no evidence that lysosomal storage of sphingolipids influences cardiac lipid content as measured by 1H-MRS. Finally, the authors share the opinion that a comprehensive cardiac examination including three subsections (LGE; 1H-MRS; T1 mapping), could hold the highest potential for the final assessment of early and late myocardial changes in Fabry disease.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predictive value of 1H MR spectroscopy and 18F-FDG PET/CT for local control of advanced oropharyngeal and hypopharyngeal squamous cell carcinoma receiving chemoradiotherapy: a prospective study

Purpose To determine whether pretreatment in vivo 1H magnetic resonance (MR) spectroscopy at 3 Tesla (T) and 18F-FDG PET/CT can offer predictive power regarding the local control of oropharyngeal or hypopharyngeal squamous cell carcinoma (OHSCC) patients. Materials and Methods 1H MR spectroscopy was performed in addition to conventional MR imaging before definitive chemoradiotherapy in 58 pat...

متن کامل

Combined 3T diffusion tensor tractography and 1H-MR spectroscopy in motor neuron disease.

BACKGROUND AND PURPOSE Diagnostic confidence in motor neuron disease may be improved by the use of advanced MR imaging techniques. Our aim was to assess the accuracy (sensitivity/specificity) and agreement of combined (1)H-MR spectroscopy (proton MR spectroscopy) and diffusion tensor imaging (DTI) at 3T in patients with suspected motor neuron disease regarding detection of upper motor neuron (U...

متن کامل

1H-MR Spectroscopy in a Case of Isolated Intracranial Rosai-Dorfman Disease

A 61-year old female presented with a headache. CT and MR imaging showed a left frontal dural-based mass mimicking meningioma. H-MR spectroscopy showed elevated lipid peaks and decreased N-aspartate, choline and creatine peaks. No abnormal alanine peak was detected. The histological diagnosis was intracranial Rosai-Dorfman disease. Our case suggests that H-MR spectroscopy provides useful inform...

متن کامل

In vivo prostate magnetic resonance imaging and magnetic resonance spectroscopy at 3 Tesla using a transceive pelvic phased array coil: preliminary results.

Magnetic resonance (MR) systems operating at 3 Telsa (T) and above have demonstrated considerable potential in human studies, offering improved signal-to-noise ratio and spectral resolution. However, because of radiofrequency limitations and concerns, and the lack of large volume body coils, most studies have been limited to the head. In this study we describe the design and construction of a t...

متن کامل

1H MR Spectroscopy of the breast cancer at 3.0-Tesla: Comparison between pre- and post- contrast administration

Introduction Proton (1H) MR Spectroscopy (MRS) of the breast cancer has been reported to be useful for the diagnosis and the assessment of treatment response to chemotherapy (1). In most reports, MRS was obtained after dynamic contrast-enhanced MRI, since voxel of interest (VOI) for MRS could be located easily referring to contrast-enhanced MRI. However there are some reports that MRS was affec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2016