Bacterial adherence to separated modular components in joint prosthesis: a clinical study.
نویسندگان
چکیده
Bacterial adherence on total joint replacement implants may lead to biofilm formation and implant-related osteoarticular infection. It is unclear if different biomaterials in the prosthetic components are more prone to facilitate this bacterial adherence, although ultrahigh molecular weight polyethylene (UHMWPE) component exchange in modular systems has been clinically utilized in the early management of these infections. To clarify if the amount of clinically adhered microorganisms was related to the material or the component, we investigated retrieved implants from infected joint replacements. Thirty-two patients were revised after confirmed implant-related infection through positive cultures. Eighty-seven total joint components (hip and knee) were obtained and separately sonicated following a previously published protocol. Cultures were quantified, and detected colony forming units (CFU) were adjusted according to the component surface and compared based on the component material and location. Variable adherence of bacteria to chrome cobalt alloys, UHMWPE, hydroxyapatite coated components, and titanium alloys. The commonest isolated organisms were Staphylococcus epidermidis (23 of 87 components) and Staphylococcus aureus (10 of 87). Twelve components did not show any microorganism adhered despite location in an infected joint, with positive cultures in other components. A mixed linear model adjusted for random effects (the random effect being the infected patient) obtained convergence for the CFU/mm(2) variable, but could not confirm a significantly higher adherence to a particular component or to a particular biomaterial. Therefore, the bacterial adherence primarily depends on the infective microorganism and the response of each individual patient, rather than materials or components.
منابع مشابه
Total Hip Arthroplasty with Modular Stem for Dysplastic Hips in South Asian Population
Introduction: Optimum component positioning and orientation is required to optimize the functional result during total hip arthroplasty for dysplastic hips. Patients and methods: Sixty-two patients (66 hips) including 33 males and 29 females underwent total hip arthroplasty using modular stem prosthesis at an average age of 40.6 years (range 17 to 49 years). Nineteen hips were clas...
متن کاملارزیابی کارایی گیت یک آمپوته همی پلویکتومی در حین راه رفتن با پروتز کانادین- گزارش موردی
Purpose: Hemipelvectomy amputation is a surgical procedure in which the lower limb and part of the pelvis are removed. Although few studies are available on the performance of individuals with hip disarticulation while walking, there is no study on gait analysis of hemipelvectomy subjects. Therefore, this study aimed to evaluate the gait and stability of an individual with hemipelvectomy amput...
متن کاملOutcome Assessment after Aptis Distal Radioulnar Joint (DRUJ) Implant Arthroplasty
Background: Conventional treatments after complicated injuries of the distal radioulnar joint (DRUJ) such as Darrach and Kapandji-Sauvé procedures have many drawbacks, which may eventually lead to a painful unstable distal ulna. The development of DRUJ prosthesis has significantly evolved over the past years. In this study, we assessed the outcome results of patients after DRUJ implant arthro...
متن کاملEffect of acceptance and commitment group therapy on benefit finding and adherence to treatment in breast cancer patients and survivors: A randomized clinical trial study
Introduction: The positive experience of life changes and the following treatment play a key role in adapting and improving breast cancer. It seems that acceptance and commitment therapy (ACT) helps this issue via facilitating acceptance and clarification of values. Therefore, the current study aimed to evaluate the effectiveness of ACT on the benefit and adherence to treatment in breast cancer...
متن کاملThe three-dimensional geometry of the proximal humerus. Implications for surgical technique and prosthetic design.
We have studied the three-dimensional geometry of the proximal humerus on human cadaver specimens using a digitised measuring device linked to a computer. Our findings demonstrated the variable shape of the proximal humerus as well as its variable dimensions. The articular surface, which is part of a sphere varies individually in its orientation as regards inclination and retroversion, and it h...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of orthopaedic research : official publication of the Orthopaedic Research Society
دوره 30 10 شماره
صفحات -
تاریخ انتشار 2012