Stability-indicating electrochemical methods for the determination of meclophenoxate hydrochloride and pyritinol dihydrochloride using ion-selective membrane electrodes.
نویسندگان
چکیده
The construction and electrochemical response characteristics of polyvinyl chloride (PVC) membrane sensors for the determination of meclophenoxate hydrochloride (I) and pyritinol dihydrochloride (II) in presence of their degradation products are described. The sensors are based on the use of the ion-association complexes of (I) and (II) cation with sodium tetraphenyl borate and ammonium reineckate counteranions as ion-exchange sites in the PVC matrix. In addition beta-cyclodextrin (beta-CD) membranes were used in the determination of I and II. These ion pairs and beta-CD were then incorporated as electroactive species with ortho nitrophenyl octyl ether (oNPOE) as a plasticizer. Three PVC sensors were fabricated for each drug, i.e. meclophenoxate tetraphenyl borate (meclo-TPB), meclophenoxate reineckate (meclo-RNC) and meclophenoxate beta-cyclodextrin (meclo-beta-CD), and the same was done for pyritinol (pyrit-TPB), (pyrit-RNC) and (pyrit-beta-CD). They showed near Nernestian responses for meclophenoxate over the concentration range 10(-5)-10(-2) with slopes of 52.73, 51.64 and 54.05 per concentration decade with average recoveries of 99.92+/-1.077, 99.96+/-0.502 and 100.03+/-0.763 for meclo-TPB, meclo-RNC and meclo-beta-CD respectively. Pyritinol also showed near Nernestian responses over the concentration range of 3.162 x 10(-6) - 3.162 x 10(-4) for pyrit-TPB and pyrit-RNC, and 10(-6) - 3.162 x 10(-4) for pyrit-beta-CD with slopes of 30.60, 31.10 and 32.89 per concentration decade and average recoveries of 99.99+/-0.827, 100.00+/-0.775 and 99.99+/-0.680 for pyrit-TPB, pyrit-RNC and pyrit-beta-CD respectively. The sensors were used successfully for the determination of I and II in laboratory prepared mixtures with their degradation products, in pharmaceutical dosage forms and in plasma.
منابع مشابه
Green Potentiometric Method for Determination of Triprolidine Hydrochloride and Pseudoephedrine Hydrochloride in their Different Pharmaceutical Matrices using Liquid and Solid Contact Gold Electrodes
Factors affecting the performance of polyvinyl chloride based ion selective electrode such as using different cationic exchangers and ionophores as well as sensor fabrication procedures were recently the scope of study by several researchers. This work presents an environment friendly electro-analytical method for the determination of Triprolidine HCl (TRI) and Pseudoephedrine HCl (PSE). A comp...
متن کاملDevelopment of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples
This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...
متن کاملDevelopment of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples
This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...
متن کاملComparison of the vanadyl-selective electrodes prepared by sol–gel and PVC membrane techniques
Sol-gel and polymeric membrane electrodes, based on thiacalix[4]arene as a neutral carrier, weresuccessfully developed for the detection of VO2+ in aqueous solutions. The sol-gel and PVCmembrane electrodes exhibited linear response with Nernstian slopes of 29.3 and 28.4 mV perdecade, respectively, within the vanadyl ion concentration ranges from 1.0 × 10-6 to 1.0 × 10-1mol dm-3 and from 1.0 × 1...
متن کاملFabrication of an Electrochemical Sensor Based on a New Nano-ion Imprinted Polymer for Highly Selective and Sensitive Determination of Molybdate
In this work a new chemically modified carbon paste electrode was constructed for accurate, simple, sensitive and selective determination of molybdenum (VI) ions. The results of modified electrode by an ion imprinted polymer were compared with those obtained with carbon paste electrode. The results showed the stripping peak currents had a dramatic increase at the modified electrode. Under the o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Yakugaku zasshi : Journal of the Pharmaceutical Society of Japan
دوره 127 1 شماره
صفحات -
تاریخ انتشار 2007