Control system for the Seismic Attenuation System (SAS) in TAMA300

نویسندگان

  • K Agatsuma
  • R Takahashi
  • K Arai
  • D Tatsumi
  • M Fukushima
  • T Yamazaki
  • M K Fujimoto
  • Y Arase
  • N Nakagawa
  • A Takamori
  • K Tsubono
  • K Kuroda
  • M Ohashi
  • R Desalvo
  • A Bertolini
  • S Márka
چکیده

A new seismic isolation system, TAMA Seismic Attenuation System (TAMA-SAS), was installed to TAMA300 in order to improve the sensitivity at low frequencies. Inertial damping is one of the hierarchical control systems of the TAMA-SAS which are employed to give full play to its ability. We have established two servo loops to control the Inverted Pendulum (IP) which composes the SAS. One is the servo loop using LVDT position sensors to keep the position of the IP. The other is the inertial damping which uses accelerometers to control the inertial motion of the IP for the horizontal direction. The fluctuation of the IP was reduced using our servo system. In addition, reduction of angular and longitudinal fluctuation of the mirror was also confirmed. These results indicate that the control for the IP properly works and the isolation performance of the TAMA-SAS was improved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Operational status of TAMA300 with the seismic attenuation system (SAS)

TAMA300 has been upgraded to improve the sensitivity at low frequencies after the last observation run in 2004. To avoid the noise caused by seismic activities, we installed a new seismic isolation system—the TAMA seismic attenuation system (SAS). Four SAS towers for the test-mass mirrors were sequentially installed from 2005 to 2006. The recycled Fabry–Perot Michelson interferometer was succes...

متن کامل

Passive-performance, analysis, and upgrades of a 1-ton seismic attenuation system

The 10 m prototype facility at the Albert–Einstein-institute (AEI) in Hanover, Germany, employs three large seismic attenuation systems to reduce mechanical motion. The AEI seismic-attenuation-system (AEI-SAS) uses mechanical anti-springs in order to achieve resonance frequencies below 0.5 Hz. This system provides passive isolation from ground motion by a factor of about 400 in the horizontal d...

متن کامل

OPTIMAL SLIDING MODE CONTROL FOR SEISMIC CONTROL OF BUILDINGS EQUIPPED WITH ATMD

Active tuned mass damper (ATMD) systems have attracted the considerable attention of researchers for protecting buildings subjected to earthquake loading. This paper presentes the development of an optimal sliding mode control (OSMC) system for a building equipped with ATMD. In the OSMC technique, a linear sliding surface is used with the slope of this surface designed such that a given (or des...

متن کامل

Peaking Attenuation in High-Gain Observers Using Adaptive Saturation: Application to a Ball and Wheel System

Despite providing robustness, high-gain observers impose a peaking phenomenon, which may cause instability, on the system states. In this paper, an adaptive saturation is proposed to attenuate the undesirable mentioned phenomenon in high-gain observers. A real-valued and differentiable sigmoid function is considered as the saturating element whose parameters (height and slope) are adaptively tu...

متن کامل

Application of Shape Memory Alloys in Seismic Isolation: A Review

In the last two decades, there has been an increasing interest in structural engineering control methods. Shape memory alloys and seismic isolation systems are examples of passive control systems that use of any one alone, effectively improve the seismic performance of the structure. Characteristics such as large strain range without any residual deformation, high damping capacity, excellent re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008