Intraoperative Transesophageal Echocardiography in the Operation of Ebstein's Anomaly: A Retrospective Study

نویسندگان

  • Xiu-Jie Tang
  • Min Bao
  • He Zhao
  • Lian-Yi Wang
  • Qing-Yu Wu
چکیده

BACKGROUND Ebstein's anomaly (EA) has various spectrums in clinical and anatomic features. This study aimed to report the experience of two-dimensional intraoperative transesophageal echocardiography (2D-ITEE) during the EA surgery and to analyze the characteristics of the tricuspid valve (TV) by comparing the data from 2D-ITEE with the results from the surgery. METHODS 2D-ITEE data of 164 patients with EA who were operated in the First Hospital of Tsinghua University between July 2004 and April 2014 were retrospectively analyzed in this study. 2D-ITEE was applied in all patients. Downward displacement distances were measured, and the numbers of downward displacement or absent leaflets were compared with that of the surgery and with that of the two-dimensional-transthoracic echocardiogram (2D-TTE). Data comparison was performed using the Chi-square test. RESULTS The anterior leaflet partial or total downward displacement was 37.76 ± 17.50 mm in 54 cases, absent in one patient; septal leaflet downward displacement was 29.07 ± 12.34 mm in 134 cases, absent in 17 cases; and posterior leaflet downward displacement was 43.18 ± 19.16 mm in 115 cases, absent in 34 cases. Statistically, there was no significant difference between the results from 2D-ITEE and that of 2D-TTE. The consistency rates of 2D-ITEE with operation for septal and posterior leaflets were 93.2% and 96.1%, respectively, while the rate for anterior was only 40.1%, which was significantly different. Color Doppler flow image showed severe regurgitation in 150 cases and moderate in 14 cases. After surgical correction, moderate regurgitation of TV was found in 58 cases with 2D-ITEE, repair was performed again until the effect was satisfied. No complication occurred relating to the use of 2D-ITEE. CONCLUSIONS 2D-ITEE could help diagnose anterior leaflet, evaluate the effect of TV repair, increase operational success rate, and reduce complication.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

eComment: re: three-dimensional transesophageal echocardiography in Ebstein's anomaly.

Three-dimensional (3D) transthoracic echocardiography has advantages over traditional two-dimensional (2D) echocardiography in visualizing tricuspid valve morphology in Ebstein's anomaly. We describe the application of intra-operative 3D transesophageal echocardiography during a tricuspid valve repair procedure in a patient with Ebstein's anomaly. Intra-operatively three-dimensional transesopha...

متن کامل

Signal-averaged electrocardiogram in Ebstein's anomaly.

We sought to establish pathogenetic links between electrophysiology, histopathology, and ventricular tachyarrhythmias in patients with Ebstein's anomaly. The atrialized right ventricle (ARV) is the site of mechanically inducible ventricular tachyarrhythmias, but relations between the arrhythmogenic substrate, the type of tachyarrhythmias, and the trigger(s) have not been established. This study...

متن کامل

Detection of patent ductus arteriosus with intraoperative transesophageal echocardiography in a patient undergoing closure of coronary artery to pulmonary artery fistula

Background Coronary artery to pulmonary artery fistula is an unusual vascular anomaly, and the shunt ratio of this fistula is usually small. Case presentation We report anesthetic management of a 55-year-old female with annuloaortic ectasia, aortic valve regurgitation, and coronary artery to pulmonary artery fistula undergoing radical repair. We calculated the left-to-right shunt ratio after ...

متن کامل

Paradoxical embolism associated with Ebstein's anomaly in an adult: case report.

Ebstein's anomaly (EA) is a rare congenital malformation of the tricuspid valve, often associated with other cardiac malformations, especially atrial septal defect, which is present in 80-90% of patients and predisposes to paradoxical embolization. We describe the case of a 47-year-old male, a drug abuser, with a known but not investigated cardiac murmur. He presented to the emergency departmen...

متن کامل

Unconventional modified Fontan operation for Ebstein's anomaly.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . doi:10.1093/ejechocard/jer230 Online publish-ahead-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 130  شماره 

صفحات  -

تاریخ انتشار 2017