Fault Detection And Diagnosis For Air Conditioners And Heat Pumps Based On Virtual Sensors

نویسندگان

  • Woohyun Kim
  • James E. Braun
  • Eckhard Groll
  • W. Travis Horton
  • Haorong Li
  • David Anderson
  • Travis W. Horton
چکیده

Kim, Woohyun. Ph.D., Purdue University, December 2013. Fault Detection and Diagnosis for Air Conditioners and Heat Pumps based on Virtual Sensors. Major Professor: James E. Braun, School of Mechanical Engineering. The primary goal of this research is to develop and demonstrate an integrated, on-line performance monitoring and diagnostic system with low cost sensors for air conditioning and heat pump equipment. Automated fault detection and diagnostics (FDD) has the potential for improving energy efficiency along with reducing service costs and comfort complaints. To achieve this goal, virtual sensors with low cost measurements and simple models were developed to estimate quantities that would be expensive and or difficult to measure directly. A virtual refrigerant charge sensor (VRC) was extended with three approaches for determining refrigerant charge for equipment having variable-speed compressors and fans. Three different virtual refrigerant mass flow (VRMF) sensors were evaluated for estimating refrigerant mass flow rate. The first model uses a compressor map that relates refrigerant flow rate to measurements of condensing and evaporating saturation temperature, and inlet temperature measurements. The second model uses a compressor energy balance with the power consumption from a virtual compressor power (VCP) sensor and energy heat loss model, which is relatively independent of compressor and expansion valve faults that influence mass flow rate. The third model was developed

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Decoupling features for diagnosis of reversing and check valve faults in heat pumps

Recently, a decoupling-based (DB) fault detection and diagnosis (FDD) method was developed for diagnosing multiple-simultaneous faults in air conditioners (AC) and was shown to have very good performance. The method relies on identifying diagnostic features that are decoupled (i.e., insensitive) to other faults and operating conditions. The current paper extends the DB FDD methodology to heat p...

متن کامل

Virtual Refrigerant Mass Flow and Power Sensors for Variable-Speed Compressors

The use of variable-speed compressors in heat pumps and air conditioners has increased in recent years in order to improve comfort and energy efficiency. At the same time, there is a trend towards embedding more sensors in this type of equipment to facilitate real-time energy monitoring and diagnostics. Although compressor mass flow rate and power consumption are useful indices for performance ...

متن کامل

On the development of a sliding mode observer-based fault diagnosis scheme for a wind turbine benchmark model

This paper addresses the design of an observer-based fault diagnosis scheme, which is applied to some of the sensors and actuators of a wind turbine benchmark model. The methodology is based on a modified sliding mode observer (SMO) that allows accurate reconstruction of multiple sensor or actuator faults occurring simultaneously. The faults are reconstructed using the equivalent output err...

متن کامل

On the development of a sliding mode observer-based fault diagnosis scheme for a wind turbine benchmark model

This paper addresses the design of an observer-based fault diagnosis scheme, which is applied to some of the sensors and actuators of a wind turbine benchmark model. The methodology is based on a modified sliding mode observer (SMO) that allows accurate reconstruction of multiple sensor or actuator faults occurring simultaneously. The faults are reconstructed using the equivalent output err...

متن کامل

Evaluation of Evaporative Cooling for Heat Transfer in the Condenser of Window-Air Conditioners

There is a demand for reduced power consumption in the vapor compression refrigeration cycle. Coefficient of performance of window-air conditioners considerably decreases and power consumption increases under very hot conditions. These problems have encouragecl studies aimed at improving the performance of window-air-conditioners by enhancing the heat transfer rate in the condenser. In this ar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015