Commutability of Possible External Quality Assessment Materials for Cardiac Troponin Measurement
نویسندگان
چکیده
BACKGROUND The measurement of cardiac troponin is crucial in the diagnosis of myocardial infarction. The performance of troponin measurement is most conveniently monitored by external quality assessment (EQA) programs. The commutability of EQA samples is often unknown and the effectiveness of EQA programs is limited. METHODS Commutability of possible EQA materials was evaluated. Commercial control materials used in an EQA program, human serum pools prepared from patient samples, purified analyte preparations, swine sera from model animals and a set of patient samples were measured for cTnI with 4 assays including Abbott Architect, Beckman Access, Ortho Vitros and Siemens Centaur. The measurement results were logarithm-transformed, and the transformed data for patient samples were pairwise analyzed with Deming regression and 95% prediction intervals were calculated for each pair of assays. The commutability of the materials was evaluated by comparing the logarithmic results of the materials with the limits of the intervals. Matrix-related biases were estimated for noncommutable materials. The impact of matrix-related bias on EQA was analyzed and a possible correction for the bias was proposed. RESULTS Human serum pools were commutable for all assays; purified analyte preparations were commutable for 2 of the 6 assay pairs; commercial control materials and swine sera were all noncommutable; swine sera showed no reactivity to Vitros assay. The matrix-related biases for noncommutable materials ranged from -83% to 944%. Matrix-related biases of the EQA materials caused major abnormal between-assay variations in the EQA program and correction of the biases normalized the variations. CONCLUSION Commutability of materials has major impact on the effectiveness of EQA programs for cTnI measurement. Human serum pools prepared from patient samples are commutable and other materials are mostly noncommutable. EQA programs should include at least one human serum pool to allow proper interpretation of EQA results.
منابع مشابه
Specimen materials, target values and commutability for external quality assessment (proficiency testing) schemes.
BACKGROUND The objective of external quality assessment is to evaluate clinical acceptability of laboratory results. It is desirable to evaluate intermethod harmonization and traceability to a reference system. METHODS Conventional matrix-modified processed materials are used in most programs, because they can be produced in large quantities, can have multiple abnormal analytes in the same vi...
متن کاملToward standardization of cardiac troponin I measurements part II: assessing commutability of candidate reference materials and harmonization of cardiac troponin I assays.
BACKGROUND Cardiac tropoin I (cTnI) measurements show an approximately 20- to 40-fold difference between assays, and better standardization and harmonization are needed. Toward this goal, the AACC cTnI Standardization Committee collaborated with the National Institute of Standards and Technology (NIST) in an earlier study to select 2 candidate reference materials (cRMs). METHODS Two troponin ...
متن کاملWhy commutability matters.
A fundamental goal of laboratory medicine is that results for patients’ samples will be comparable independent of the medical laboratory that produced the results. Routine measurement procedures of acceptable analytical specificity that have calibration traceable to the same higherorder reference material or reference measurement procedure should produce numerical values for clinical samples th...
متن کاملTime-dependent instability of cardiac troponins in human plasma spiked with NIST reference material 2921.
An important prerequisite for guaranteeing comparability of results among cardiac troponin I (cTnI) assays is the availability of a reference system, including a secondary, matrix-based reference material (1 ). Presently only the NIST Standard Reference Material (SRM) 2921 is available (2 ). This purified primary material has partial commutability characteristics, making it inadequate for direc...
متن کاملThe importance of commutability of reference materials used as calibrators: the example of ceruloplasmin.
BACKGROUND Different methods for ceruloplasmin tend to give different results in external quality assessment schemes. During the production of the certified reference material ERM-DA470k/IFCC discrepant measurement results were also found for ceruloplasmin measured with different methods, and consequently the protein could not be certified in the material. METHODS We performed a commutability...