Flow-through partial-filling affinity capillary electrophoresis can estimate binding constants of neutral ligands to receptors via a competitive assay technique.

نویسندگان

  • John Kaddis
  • Erica Mito
  • Joseph Heintz
  • Alfredo Plazas
  • Frank A Gomez
چکیده

This work evaluates the use of a competitive binding assay using flow-through partial-filling affinity capillary electrophoresis (FTPFACE) to estimate binding constants of neutral ligands to a receptor. We demonstrate this technique using, as a model system, carbonic anhydrase B (CAB, EC 4.2.1.1) and arylsulfonamides. In this technique, the capillary is first partially filled with a negatively charged ligand, a sample containing CAB and two noninteracting standards, and a neutral ligand, then electrophoresed. Upon application of a voltage the sample plug migrates into the plug of negatively charged ligand (L(-)) resulting in the formation of a CAB-L(-) complex. Continued electrophoresis results in mixing between the neutral ligand (L(0)) and the CAB-L(-) complex. L(0) successfully competes out L(-) to form the new CAB-L(0) complex. Analysis of the change in the relative migration time ratio (RMTR) of CAB relative to the noninteracting standards, as a function of neutral ligand concentration, yields a value for the binding constant. These values are in agreement with those estimated using other binding and ACE techniques. Data demonstrating the quantitative potential of this method is presented.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of chemometric methodology in optimizing conditions for competitive binding partial filling affinity capillary electrophoresis.

This work expands the knowledge of the use of chemometric response surface methodology (RSM) in optimizing conditions for competitive binding partial filling ACE (PFACE). Specifically, RSM in the form of a Box-Behnken design was implemented in flow-through PFACE (FTPFACE) to effectively predict the significance of injection time, voltage, and neutral ligand (neutral arylsulfonamide) concentrati...

متن کامل

Partial-filling affinity capillary electrophoresis techniques to probe the binding of glycopeptide antibiotics to D-Ala-D-Ala terminus peptides.

This work is an overview of our use of affinity capillary electrophoresis (ACE) to estimate binding constants between D-Ala-D-Ala terminus peptides and the glycopeptides vancomycin (Van) from Streptomyces orientalis, teicoplanin (Teic) from Actinoplanes teicomyceticus, and ristocetin A (Rist) from Nocardia lurida. In these studies, modifications in the ACE technique, including partial-filling A...

متن کامل

Partial-filling affinity capillary electrophoresis.

Partial-filling affinity capillary electrophoresis (PFACE) is used to examine the binding interactions between two model biological systems: D-Ala-D-Ala terminus peptides to the glycopeptide antibiotic vancomycin (Van) from Streptomyces orientalis, and arylsulfonamides to carbonic anhydrase B (CAB, EC 4.2.1.1, bovine erythrocytes). Using these two systems, modifications in the PFACE technique a...

متن کامل

Optimum Conditions of Radioligand Receptor Binding Assay of Ligands of Benzodiazepine Receptors

To obtain drugs which are more selective at benzodiazepine (BZD) receptors, design and synthesis of functionally selective ligands for BZD receptors is the current strategy of our pharmaceutical chemistry department. The affinity of newly synthesized ligands is assessed by radioligand receptor binding assays. Based on our previous studies, 2-phenyl-5-oxo-7-methyl-1,3,4-oxadiazolo[a,2,3]-pyrimid...

متن کامل

Multiple-step ligand injection affinity capillary electrophoresis for determining binding constants of ligands to receptors.

This work demonstrates the use of multiple-step ligand injection affinity capillary electrophoresis (ACE) using two model systems: vancomycin from Streptomyces orientalis and carbonic anhydrase B (CAB, EC 4.2.1.1). In this technique a sample plug of receptor and non-interacting standards is injected by pressure and electrophoresed in a buffer containing a given concentration of ligand. The sequ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Electrophoresis

دوره 24 6  شماره 

صفحات  -

تاریخ انتشار 2003