Biomechanical evaluation of a biomimetic spinal construct

نویسندگان

  • Tian Wang
  • Jonathon R Ball
  • Mattew H Pelletier
  • William R Walsh
چکیده

BACKGROUND Laboratory spinal biomechanical tests using human cadaveric or animal spines have limitations in terms of disease transmission, high sample variability, decay and fatigue during extended testing protocols. Therefore, a synthetic biomimetic spine model may be an acceptable substitute. The goal of current study is to evaluate the properties of a synthetic biomimetic spine model; also to assess the mechanical performance of lateral plating following lateral interbody fusion. METHODS Three L3/4 synthetic spinal motion segments were examined using a validated pure moment testing system. Moments (±7.5 Nm) were applied in flexion-extension (FE), lateral bending (LB) and axial rotation (AR) at 1Hz for total 10000 cycles in MTS Bionix. An additional test was performed 12 hours after 10000 cycles. A ±10 Nm cycle was also performed to allow provide comparison to the literature. For implantation evaluation, each model was tested in the 4 following conditions: 1) intact, 2) lateral cage alone, 3) lateral cage and plate 4) anterior cage and plate. Results were analysed using ANOVA with post-hoc Tukey's HSD test. RESULTS Range of motion (ROM) exhibited logarithmic growth with cycle number (increases of 16%, 37.5% and 24.3% in AR, FE and LB respectively). No signification difference (p > 0.1) was detected between 4 cycles, 10000 cycles and 12 hour rest stages. All measured parameters were comparable to that of reported cadaveric values. The ROM for a lateral cage and plate construct was not significantly different to the anterior lumbar interbody construct for FE (p = 1.00), LB (p = 0.995) and AR (p = 0.837). CONCLUSIONS Based on anatomical and biomechanical similarities, the synthetic spine tested here provides a reasonable model to represent the human lumbar spine. Repeated testing did not dramatically alter biomechanics which may allow non-destructive testing between many different procedures and devices without the worry of carry over effects. Small intra-specimen variability and lack of biohazard makes this an attractive alternative for in vitro spine biomechanical testing. It also proved an acceptable surrogate for biomechanical testing, confirming that a lateral lumbar interbody cage and plate construct reduces ROM to a similar degree as anterior lumbar interbody cage and plate constructs.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical and Histological Evaluation of an Allograft Anchor for Pedicle Screw Augmentation in an Ovine Model

INTRODUCTION Achieving solid implant fixation to osteoporotic bone presents a challenge to both spinal surgeons and hardware designers. Loss of surgical construct stability as a result of screw loosening is a well-known complication [1,2], particularly in patients with poor bone quality [3,4]. Thus, the development of novel strategies to address the issue of obtaining enhanced bone-to-screw pur...

متن کامل

Biomimetic Spider Leg Joints: A Review from Biomechanical Research to Compliant Robotic Actuators

Due to their inherent compliance, soft actuated joints are becoming increasingly important for robotic applications, especially when human-robot-interactions are expected. Several of these flexible actuators are inspired by biological models. One perfect showpiece for biomimetic robots is the spider leg, because it combines lightweight design and graceful movements with powerful and dynamic act...

متن کامل

Biomechanical Comparison of Posterior Fixation Using Spinal Instrumentation and Conventional Posterior Plate Fixation in Unstable Vertical Sacral Fracture.

Vertical sacral fracture is one of the most difficult fractures to treat. Posterior fixation using spinal dual rods is a novel method for treating this fracture, but its biomechanical strength has not yet been reported. The aim of this study was to evaluate the biomechanical strength produced by posterior fixation using spinal instrumentation. Sacral fractures were created in eight pelvic bone ...

متن کامل

Evaluation of tendon healing using fibroblast like synoviocytes in rabbits: A biomechanical study

Tendon never restores the complete biological and mechanical properties after healing. Several techniques are available for tissue-engineered biological augmentation for tendon healing like stem cells. Recently, synovium has been investigated as a source of cells for tissue engineering. In the present study, we investigated potentials of fibroblast like synoviocytes (FLSs) in tendon healing. Si...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2014