Evaluation of 4 new generation portable ventilators.

نویسندگان

  • Thomas C Blakeman
  • Richard D Branson
چکیده

BACKGROUND Portable ventilators are increasingly utilized in the intra- and inter-hospital transport of patients. We evaluated 4 portable ventilators, Impact EMV, CareFusion LTV 1200, Newport HT70, and Hamilton T1, in terms of triggering, delivered tidal volume (V(T)) accuracy, battery duration, delivered F(IO(2)) accuracy, and gas consumption. METHODS Triggering was tested using a microprocessor controlled breathing simulator that simulated a weak, normal, and aggressive inspiratory effort using muscle pressures of -2, -4, and -8 cm H2O respectively. Delivered V(T) and F(IO(2)) accuracy were evaluated across a range of operation. To determine gas consumption, the ventilators were attached to an E type oxygen cylinder and operated at an F(IO(2)) of 1.0 until the tank was depleted. Battery duration was tested by operating each ventilator at an F(IO(2)) of 0.21 until the device ceased to operate. RESULTS Differences remain among devices in several aspects of the testing protocol. Gas consumption ranged from 9.2 to 16 L/min. Battery duration ranged from 101 to 640 min. Triggering performance varied among devices but was consistent breath to breath within the same device, using the fastest and slowest rise time settings. F(IO(2)) accuracy varied at the low range on the 50 mL V(T) setting with one device, and at the high range on both the 50 mL and 500 mL V(T) settings with another. CONCLUSIONS Manufacturers continue to improve the performance of portable ventilators. All the ventilators we tested performed well on V(T) delivery across a range of settings, using both the internal drive mechanism (F(IO(2)) 0.21) and compressed oxygen (F(IO(2)) 1.0). Two of the ventilators were unable to deliver accurate F(IO(2)) across the range of V(T). None of the devices was clearly superior to the others in all aspects of our evaluation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An evaluation of home volume ventilators that support open-circuit mouthpiece ventilation.

BACKGROUND Open-circuit mouthpiece ventilation (MPV) is a form of noninvasive ventilation that can be used to provide portable daytime ventilatory support for neuromuscular patients with chronic respiratory failure. MPV has been reported to reduce the risk of respiratory infection due to tracheostomy, and to improve cough and voice function and patient quality of life. Despite these potential b...

متن کامل

Evaluation of the user interface simplicity in the modern generation of mechanical ventilators.

OBJECTIVE We designed this study to evaluate the simplicity of the user interface in modern-generation mechanical ventilators. We hypothesized that different designs in the user interface could result in different rates of operational failures. SETTING A laboratory in a tertiary teaching hospital. DESIGN Crossover design. SUBJECTS Twenty-one medical resident physicians who did not possess...

متن کامل

Evaluation of the ventilator-user interface of 2 new advanced compact transport ventilators.

BACKGROUND Mechanical ventilation during patient transport frequently utilizes compact portable pneumatic ventilators that have limited ventilator-settings options. New advanced transport ventilators should yield quality improvements, but their user-friendliness needs to be tested. OBJECTIVE To evaluate the ventilator-user interface of 2 new transport ventilators. METHODS This was a 2-cente...

متن کامل

New generation neonatal high frequency ventilators: effect of oscillatory frequency and working principles on performance.

BACKGROUND Several new generation neonatal ventilators that incorporate conventional as well as high frequency ventilation (HFOV) have appeared on the market. Most of them offer the possibility to use HFOV in a volume-targeted mode, despite absence of any preclinical data. With a bench test, we evaluated the performances of 4 new neonatal HFOV devices and compared them to the SensorMedics HFOV ...

متن کامل

Inter- and intra-hospital transport of the critically ill.

Intra- and inter-hospital transport is common due to the need for advanced diagnostics and procedures, and to provide access to specialized care. Risks are inherent during transport, so the anticipated benefits of transport must be weighed against the possible negative outcome during the transport. Adverse events are common in both in and out of hospital transports, the most common being equipm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Respiratory care

دوره 58 2  شماره 

صفحات  -

تاریخ انتشار 2013