Performance Evaluation of Pv Ventilated Glazing

نویسندگان

  • Tin-tai Chow
  • Zhongzhu Qiu
  • Chunying Li
چکیده

This paper reports the simulation approach and prediction of annual energy performance of PV ventilated glazing systems with daylight saving as applying to typical office environment. Our computer model was developed via the ESP-r simulation platform in association with the RADIANCE lighting software. The new attempt of using indirect interaction between the two simulation programs through daylight coefficient, together with the coupled air-flow network and energy balance technique, has been proved very useful in tackling this kind of long period analysis. The simulation results show that for the range of climate regions from tropical to temperate, the PV natural-ventilated glazing system has advantages over the absorptive natural-ventilated glazing option as well as the single-pane glazing systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Evaluation of the Photovoltaic Double-skin Facade

The mathematic models for thermal, and PV solar power inserted in the ESP-r, which is the integrating building energy and environment simulation tool, were verified with the measured da ta. Using the verified model, the energy performance of an office building, equipped toward the south with conventional absorptive single facade or unventilated double PV facade or outward ventilated double PV f...

متن کامل

Assessment of the Performance of a Ventilated Window Coupled with a Heat Recovery Unit through the Co-Heating Test

The aim of the article is to describe the results of an experimental campaign based on the assessment of a heat recovery unit coupled with a dynamic window. Two fully monitored and calibrated outdoor test cells are used, in order to evaluate the energy performance and the related thermal comfort. The former presents a traditional window with double-glazing, aluminum frame and indoor blind and a...

متن کامل

Analysis of the Performance of Vacuum Glazing in Office Buildings in Korea: Simulation and Experimental Studies

Window performance in buildings is very important for energy saving. Many efforts have been made towards saving energy in buildings, and research has focused attention on enhancing the thermal performance of windows. Vacuum glazing has attracted much interest as a means of enhancing the thermal performance of windows by strengthening insulation performance. However, the performance of vacuum gl...

متن کامل

PERFORMANCE OF ffiGH-PERFORMANCE GLAZING IN IECC COMPLIANT BUILDING SIMULATION MODEL

Current specifications for glazing in the 2000 IECC code adopted by Texas imply the use of low-E glazing. However, the trends in the development of high­ performance glazing technology indicate that windows have the potential to provide net positive energy benefits making it inevitable for future versions of the IECC to incorporate high-performance glazing. This study examines the performance o...

متن کامل

Analysis of Temperature Effect on a Crystalline Silicon Photovoltaic Module Performance

In this paper, the effect of the cell-temperature on the performance of photovoltaic (PV) module is evaluated. The evaluation is based on a mathematical module (single diode equivalent circuit) and practically based on solar module tester (SMT). Solara®130W PV crystalline silicon module was used in this simulation. The SMT is able to supply a constant irradiance level (1000W/m2) or any other de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009