Comparison of sodium ion levels between an arterial blood gas analyzer and an autoanalyzer in preterm infants admitted to the neonatal intensive care unit: a retrospective study
نویسندگان
چکیده
BACKGROUND The difference in sodium ion levels determined with direct and indirect methods often exceeds the permissible limit clinically. Additionally, no previous study has assessed the difference in the sodium ion levels between direct and indirect methods in premature infants. Therefore, the present study aimed to compare sodium ion levels obtained using an arterial blood gas analyzer (ABGA; direct method) and an autoanalyzer (indirect method) to determine whether they are equivalent in premature infants. METHODS The present retrospective study included 450 preterm infants (weight, <2500 g) who were admitted to the neonatal intensive care unit (NICU) of our hospital between March 2012 and April 2014. We compared sodium ion levels in 1041 samples analyzed using an ABGA (Stat Profile® CCX Series, Nova Biomedical, Waltham, MA) and an autoanalyzer (ADVIA® 2400 Clinical Chemistry System, Siemens, Tarrytown, NY). The data were evaluated using Spearman's correlation coefficient analysis, Bland-Altman plot, Deming regression analysis, and multivariate logistic regression analysis. RESULTS The mean sodium ion levels were 134.6 ± 3.5 mmol/L using the ABGA and 138.8 ± 4.7 mmol/L using the autoanalyzer (P < 0.001). Among the 1041 samples, 957 (91.9 %) showed lower sodium ion levels with the ABGA than with the autoanalyzer and 74 (7.1 %) showed lower sodium ion levels with the autoanalyzer than with the ABGA. The incidence of hyponatremia identified using the ABGA was 51.9 % (541/1041), while the incidence of hyponatremia identified using the autoanalyzer was only 14.0 % (146/1041). The Deming regression analysis of the sodium ion levels between the ABGA and the autoanalyzer yielded the following formula: autoanalyzer Na (mmol/L) = 20.7 + (0.9 × ABGA Na [mmol/L]). In the multivariate logistic regression analysis, low plasma protein level (<4.3 g/dL) was found to be an independent risk factor for a sodium ion level difference of >4 mmol/L between the two methods (odds ratio = 2.870, P < 0.001). CONCLUSION The sodium ion levels determined using the ABGA and the autoanalyzer might not be equivalent in premature infants admitted to the NICU. Therefore, clinicians should be careful when diagnosing sodium ion imbalance in premature infants and providing treatment.
منابع مشابه
The effect of Yakson touch on neonatal weight of premature infants admitted to the intensive care unit of Taleghani Hospital in Gonbad Kavous 2020
.1 Semnani N, Hojjati H, Akhoundzadeh G. The Effect of Yakson Touch on Pain Control Due to Nasogastric Intubation in Premature Infants Admitted to the Neonatal Intensive Care Unit of Taleghani Gonbad Hospital in 2019. arumshcj. 2020;22(2):93-101. .2 Hanieh Sajadi GAHH. The Effect of Empowerment Program on Participation of Mothers with Premature Infants Hospitalized in Neonatal Intensive Care U...
متن کاملImpact of Hyperglycemia Duration on Mortality and Ventilator Dependence in Neonatal Intensive Care Unit
Background: Hyperglycemia is an independent risk factor for mortality in neonatal intensive care units (NICU).Herein, we aimed to investigate the relationship of hyperglycemia duration with mortality and ventilator dependence in infants admitted to NICU.Methods: In this original retrospective study, data was collected between October 2015 and December 2015 from NICU of Dr. Sheikh Children’s Hos...
متن کاملCorrelations of Handling Procedures and Sleep Patterns of the Infants Admitted to the Neonatal Intensive Care Unit
Background: The present study aimed to assess handling procedures and their effects on the sleep-wake time in the preterm infants admitted to the neonatal intensive care unit (NICU). Methods: This observationalcross-sectional study was conducted in the NICU ofVali-e-Asr Teaching Hospital affiliated to Tehran University of Medical Sciences (TUMS), Iran in 2016. Sample population consisted of 15...
متن کاملThe Effect of Plastic Cover on Regulation of Vital Signs in Preterm Infants: A Randomized Cross-over Clinical Trial
Background: Considering the susceptibility of preterm infants to disturbances of vital signs, this study was conducted to investigate the effects of using plastic covers on regulation of vital signs in preterm neonates.Methods: This randomized, cross-over, clinical trial was carried out on 80 preterm infants admitted to neonatal intensive care unit (NICU) of Taleghani Hospital, Tabriz, Iran. Th...
متن کاملThe relationship between pain score and its effective indices in neonatal endotracheal open suction under ventilator
Aims and background: Although suctioning is an important nursing intervention in neonates under mechanical ventilation, it can lead to complications such as pain, respiratory distress, hypoxemia, bronchospasm and hospital infection. The purpose of this study was to determine the relationship between pain score and its effective indices in neonatal endotracheal open suction under ventilator in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 16 شماره
صفحات -
تاریخ انتشار 2016