Comparison of the Vacuum Mattress versus the Spine Board Alone for Immobilization of the Cervical Spine Injured Patient: A Biomechanical Cadaveric Study.
نویسندگان
چکیده
STUDY DESIGN A biomechanical cadaveric study. OBJECTIVE We sought to determine the amount of motion generated in an unstable cervical spine fracture with use of the vacuum mattress versus the spine board alone. Our hypothesis is that the vacuum mattress will better immobilize an unstable cervical fracture. SUMMARY OF BACKGROUND DATA Trauma patients in the United States are immobilized on a rigid spine board, whereas in many other places, vacuum mattresses are used with the proposed advantages of improved comfort and better immobilization of the spine. METHODS Unstable subaxial cervical injuries were surgically created in five fresh whole human cadavers. The amount of motion at the injured motion segment during testing was measured using a Fastrak, three-dimensional, electromagnetic motion analysis device (Polhemus Inc.). The measurements recorded in this investigation included maximum displacements during application and removal of the device, while tilting to 90°, during a bed transfer, and a lift onto a gurney. Linear and angular displacements were compared using the Generalized Linear Model analysis of variance for repeated measures for each of the six dependent variables (three planes of angulations and three axes of displacement). RESULTS There was more motion in all six planes of motion during the application process with use of the spine board alone, and this was statistically significant for axial rotation (P = 0.011), axial distraction (P = 0.035), medial-lateral translation (P = 0.027), and anteroposterior translation (P = 0.026). During tilting, there was more motion with just the spine board, but this was only statistically significant for anteroposterior translation (P = 0.033). With lifting onto the gurney, there was more motion with the spine board in all planes with statistical significance, except lateral bending. During the removal process, there was more motion with the spine board alone, and this was statistically significant for axial rotation (P = 0.035), lateral bending (P = 0.044), and axial distraction (P = 0.023). CONCLUSION There was more motion when using a spine board alone during typical maneuvers performed during early management of the spine injured patient than the vacuum mattress. There may be benefit of use of the vacuum mattress versus the spine board alone in preventing motion at an unstable, subaxial cervical spine injury. LEVEL OF EVIDENCE 2.
منابع مشابه
A Comparison of Cervical Spine Motion After Immobilization With a Traditional Spine Board and Full-Body Vacuum-Mattress Splint
Background The National Athletic Trainers' Association (NATA) advocates for cervical spine immobilization on a rigid board or vacuum splint and for removal of athletic equipment before transfer to an emergency medical facility. Purpose To (1) compare triplanar cervical spine motion using motion capture between a traditional rigid spine board and a full-body vacuum splint in equipped and unequ...
متن کاملCervical Spine Alignment During On-Field Management of Potential Catastrophic Spine Injuries
CONTEXT When cervical spine injuries are suspected, the cervical spine should be immobilized in a neutral position and neck motion controlled in preparation for transport to an emergency facility. Protocols for emergency transport utilizing common devices (cervical collars) and methods (transfer techniques) during these procedures are not entirely evidence based. EVIDENCE ACQUISITION The medi...
متن کاملDebunking Dogma in the ED- Bridging the Knowledge Translation gap to Bring Cutting Edge Care to the Bedside
Field spinal immobilization using a backboard and cervical collar has been standard practice for patients with suspected spine injury since the 1960s. The backboard has been a component of field spinal immobilization despite lack of efficacy evidence. While the backboard is a useful spinal protection tool during extrication, use of backboards is not without risk, as they have been shown to caus...
متن کاملPain and tissue-interface pressures during spine-board immobilization.
STUDY OBJECTIVES Although spine boards are one of the main EMS means of immobilization and transportation, few studies have addressed the discomfort and potential harmful consequences of using this common EMS tool. We compared the levels of pain and tissue-interface (contact) pressures in volunteers immobilized on spine boards with and without interposed air mattresses. DESIGN Prospective cro...
متن کاملImage Quality and Entrance Surface Dose Evaluation of Lateral Cervical Spine: A Study Using Grid and Non-Grid Techniques
Introduction: The purpose of this study is to investigate the effects of grid and non-grid techniques in the lateral cervical spine radiography on image quality and entrance surface dose (ESD). Although image quality and radiation doses have been studied by researchers, there is still a dearth of information on image quality and patient dose with different techniques. Material and Methods: The...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Spine
دوره 42 24 شماره
صفحات -
تاریخ انتشار 2017