A Comparative Data-Based Modeling Study on Respiratory CO2 Gas Exchange during Mechanical Ventilation

نویسندگان

  • Chang-Sei Kim
  • J. Mark Ansermino
  • Jin-Oh Hahn
چکیده

The goal of this study is to derive a minimally complex but credible model of respiratory CO2 gas exchange that may be used in systematic design and pilot testing of closed-loop end-tidal CO2 controllers in mechanical ventilation. We first derived a candidate model that captures the essential mechanisms involved in the respiratory CO2 gas exchange process. Then, we simplified the candidate model to derive two lower-order candidate models. We compared these candidate models for predictive capability and reliability using experimental data collected from 25 pediatric subjects undergoing dynamically varying mechanical ventilation during surgical procedures. A two-compartment model equipped with transport delay to account for CO2 delivery between the lungs and the tissues showed modest but statistically significant improvement in predictive capability over the same model without transport delay. Aggregating the lungs and the tissues into a single compartment further degraded the predictive fidelity of the model. In addition, the model equipped with transport delay demonstrated superior reliability to the one without transport delay. Further, the respiratory parameters derived from the model equipped with transport delay, but not the one without transport delay, were physiologically plausible. The results suggest that gas transport between the lungs and the tissues must be taken into account to accurately reproduce the respiratory CO2 gas exchange process under conditions of wide-ranging and dynamically varying mechanical ventilation conditions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extracorporeal gas exchange and spontaneous breathing for the treatment of acute respiratory distress syndrome: an alternative to mechanical ventilation?*.

OBJECTIVES Venovenous extracorporeal gas exchange is increasingly used in awake, spontaneously breathing patients as a bridge to lung transplantation. Limited data are available on a similar use of extracorporeal gas exchange in patients with acute respiratory distress syndrome. The aim of this study was to investigate the use of extracorporeal gas exchange in awake, spontaneously breathing she...

متن کامل

Theoretical Study of Inspiratory Flow Waveforms during Mechanical Ventilation on Pulmonary Blood Flow and Gas Exchange

A lumped two-compartment mathematical model of respiratory mechanics incorporating gas exchange and pulmonary circulation is utilized to analyze the effects of square, descending and ascending inspiratory flow waveforms during mechanical ventilation. The effects on alveolar volume variation, alveolar pressure, airway pressure, gas exchange rate, and expired gas species concentration are evaluat...

متن کامل

Heliox Improves Carbon Dioxide Removal during Lung Protective Mechanical Ventilation

Introduction. Helium is a noble gas with low density and increased carbon dioxide (CO2) diffusion capacity. This allows lower driving pressures in mechanical ventilation and increased CO2 diffusion. We hypothesized that heliox facilitates ventilation in patients during lung-protective mechanical ventilation using low tidal volumes. Methods. This is an observational cohort substudy of a single a...

متن کامل

Iron lung versus conventional mechanical ventilation in acute exacerbation of COPD.

The aim of this randomised study was to compare the effects of iron lung ventilation (ILV) with invasive mechanical ventilation (IMV) in patients with acute respiratory failure (ARF) due to exacerbation of chronic obstructive pulmonary disease. Forty-four patients with ARF were assigned either to ILV (22 patients) or IMV (22 patients). Primary end-points were the improvement in gas exchange and...

متن کامل

تأثیر تهویه با حجم‌های جاری متفاوت و تهویه دقیقه‌ای ثابت بر روی دی‌اکسید کربن انتهای بازدمی

Background & Aims: Elimination of carbon dioxide is related to the alveolar ventilation, respiratory rate and tidal volume. The aim of this study  to determine the effect of mechanical ventilation with different tidal volumes and constant minute ventilation on the end tidal Co2  and oxygen saturation during general anesthesia and to seek optimum parameters of mechanical ventilation during gener...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2016