Anterior chamber angle imaging with swept-source optical coherence tomography: an investigation on variability of angle measurement.

نویسندگان

  • Shu Liu
  • Marco Yu
  • Cong Ye
  • Dennis S C Lam
  • Christopher Kai-Shun Leung
چکیده

PURPOSE To evaluate the reproducibility of anterior chamber angle measurements obtained by swept-source optical coherence tomography (OCT) and to identify factors associated with its measurement variability. METHODS One eye from each of 30 healthy subjects was randomly selected for anterior segment OCT imaging (Casia SS-1000 OCT; Tomey, Nagoya, Japan) in three separate visits within a week. The angle opening distance (AOD), the trabecular iris space area (TISA), and the trabecular-iris angle (TIA) at the superior (90°), nasal (0°), inferior (270°), and temporal (180°) angles were measured. The intraobserver and interobserver reproducibility coefficient (RC) and intraclass correlation coefficient (ICC) were calculated. Generalized linear latent and mixed modeling was used to examine the association between the variance of angle measurements and each of the following: angle width, pupil diameter, pupil diameter variance, iris thickness, iris thickness variance, axial length, anterior chamber depth, scan location, scleral spur visibility, and age. RESULTS The intervisit, intraobserver RCs ranged between 0.140 mm and 0.252 mm for AOD, 0.050 mm(2) and 0.090 mm(2) for TISA, and 7.7° and 9.5° for TIA, and the interobserver RCs were between 0.103 mm and 0.187 mm, 0.049 mm(2) and 0.101 mm(2), and 8.5° and 13.7°, respectively. The ICCs were all ≥0.83. Increased iris thickness, increased iris thickness variance, angle measured at the superior and inferior quadrants, increased angle width, and long axial length were associated with increased variance of angle measurements. CONCLUSIONS Although the swept-source OCT had high reproducibility for angle measurement, differences in iris thickness, angle width, measurement location, and axial length may influence its variability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of Anterior Segment Measurements with Swept Source Optical Coherence Tomography before and after Ab Interno Trabeculotomy (Trabectome) Surgery

Purpose. To compare the changes of anterior segment parameters, assessed by swept source anterior segment optical coherence tomography (AS-OCT) after combined Trabectome-cataract surgery and Trabectome-only surgery in open angle glaucoma patients. Methods. Thirty-eight eyes of 24 patients with open angle glaucoma were scanned with swept source AS-OCT before and 4 weeks after combined Trabectome...

متن کامل

Investigation of the variability of anterior chamber scan protocol with Cirrus high definition optical coherence tomography.

IMPORTANCE The evaluation of anterior chamber scan of Cirrus optical coherence tomography for routine clinical use. BACKGROUND To assess the variability of anterior chamber angle measurements. DESIGN This was a cross-sectional study. PARTICIPANTS Forty subjects aged 40-80 years were included. METHODS One randomly selected eye from 40 subjects was imaged with Cirrus optical coherence tom...

متن کامل

Reproducibility of anterior chamber angle analyses with the swept-source optical coherence tomography in young, healthy Caucasians.

PURPOSE To assess the reproducibility of iridocorneal angle (ICA) analysis in young, healthy Caucasian subjects using swept-source optical coherence tomography (SS-OCT) by determining variability and interobserver agreement between expert and nonexpert observers. METHODS Thirty-one healthy volunteers (nonexperts) acquired three consecutive SS-OCT images of the right eyes of their peer nonexpe...

متن کامل

Reference values for anterior chamber morphometrics with swept-source optical coherence tomography in a Caucasian population

Purpose The aim of this study is to generate reference values for anterior chamber morphometrics to facilitate the interpretation of anterior chamber images acquired with swept-source optical coherence tomography (SS-OCT) in a Caucasian population. Materials and methods Non-glaucomatous Caucasian subjects, who were newly referred to the outpatient department of the University Eye Clinic Maast...

متن کامل

Anterior Segment Optical Coherence Tomography and its Clinical Applications in Glaucoma

Anterior segment optical coherence tomography (ASOCT) is an imaging modality that provides both quantitative and qualitative information on the cornea, anterior chamber angle, iris and crystalline lens. ASOCT shows excellent repeatability and reproducibility for the measurement of corneal thickness, anterior chamber angle and anterior chamber depth. With realtime video recording, ASOCT can also...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 52 12  شماره 

صفحات  -

تاریخ انتشار 2011