Contamination by metallic elements released from joint prostheses.

نویسندگان

  • E Chassot
  • J L Irigaray
  • S Terver
  • G Vanneuville
چکیده

When a metallic implant is in contact with human tissues, the organism reacts and a corrosion process starts. Consequently, we might observe liberation of metallic debris and wear. Our purpose is to measure the contamination and the migration of these metallic elements in the surrounding tissues of the implant. Two types of samples have been studied. First type is sample taken on post-mortem tissues around prostheses to study contamination gradients. Second type is sample taken on pathologic joints on periprosthetic capsular tissues in surgical conditions. These allow estimating contamination degree. The experiments were made on a Van de Graaff accelerator located at CERI (Centre d'Etude et de Recherche par Irradiation, Orléans, France). We measure elemental concentrations resulting from the contamination of the surface of each sample. Results are analysed in function of the pathology and the type of implants. According to the pathology and the location of the sampling, these measurements show a very heterogeneous contamination by metallic elements under particles and/or ionic species which can migrate through soft tissues by various mechanisms.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ecological Risk Assessment of Some Heavy Metals in the Dust Emitted from Non-Metallic Industries of Ardakan County of Yazd in Summer 2018: A Descriptive Study

Background and Objectives: Implementation of industrial development programs, without considering environmental considerations has caused continuous entrance of pollutants to air. Therefore, the purpose of this study was assessing the ecological risk of some heavy metals in the dust of a number of non-metallic industries and determining the best indices in pollution assessment of Ardakan area. ...

متن کامل

The CT number accuracy of a novel commercial metal artifact reduction algorithm for large orthopedic implants

Philips Healthcare released a novel metal artifact reduction algorithm for large orthopedic implants (O-MAR). Little information was available about its CT number accuracy. Since CT numbers are used for tissue heterogeneity corrections in external beam radiotherapy treatment planning, we performed a phantom study to assess the CT number accuracy of O-MAR. Two situations were simulated: a patien...

متن کامل

Adverse tissue reactions to wear particles from Co-alloy articulations, increased by alumina-blasting particle contamination from cementless Ti-based total hip implants. A report of seven revisions with early failure.

We revised seven alumina-blasted cementless hip prostheses (Ti-alloy stems, cp Ti threaded sockets) with low- or high-carbon Co-alloy bearings at a mean of 20.1 months after implantation because of pain and loosening. Histological examination of the retrieved periprosthetic tissues from two cases in which the implant was stable and three in which the socket was loose showed macrophages with bas...

متن کامل

Size of metallic and polyethylene debris particles in failed cemented total hip replacements.

Reports of differing failure rates of total hip prostheses made of various metals prompted us to measure the size of metallic and polyethylene particulate debris around failed cemented arthroplasties. We used an isolation method, in which metallic debris was extracted from the tissues, and a non-isolation method of routine preparation for light and electron microscopy. Specimens were taken from...

متن کامل

Contamination and oxydation degre of metallic elements in periprosthetic tissues

The metallic prosthesis used in orthopaedic surgery undergo degradations some years after their implantation. This phenomenon induces metallic element transfer in surrounding tissues. On postmortem and per-operatory samples, we have taken tissues around hip or knee prosthesis. We have determined the composition of the implanted prosthesis by spark spectrometer. In the first step, we manufacture...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical engineering & physics

دوره 26 3  شماره 

صفحات  -