Analysis of an Optical Coherence Imaging Modality on the Detection of an Abnormality in Biological Tissue with a Nanoparticle Contrast Agent
نویسنده
چکیده
There is great interest in promoting the use of contrast agents in optical imaging for better diagnosis of diseases. However, until recently, there was still no quantitative method existing to assess the ability of contrast agents in improving clinical diagnosis. In this study, we used the method of task-based medical image analysis as a quantitative tool to evaluate the e¤ectiveness of nanoparticles as contrast agents in an OCT imaging modality for clinical diagnosis. The task was formulated as the detection of abnormalities in a biological tissue using a quadratic observer. We derived the test statistics of the quadratic observer, and an analytical expression for the index of detectability for such a quadratic observer. The statistical properties of the OCT data are determined by the stochastic mechanisms in the imaging system as well as the demodulation method in the data acquisition process. In this analysis, we have considered the e¤ect of phase uctuations from the broadband source, the shot noise uctuations of the imaging system, and the scattering noise due to refractive index uctuation in the biological tissue. Our analysis was performed at the system level by integrating to the analysis the data demodulation process based on a mixer scheme. Also, we implemented the dynamic focusing in the scanning process. Optical propagation in biological samples is dominated by scattering due to uctuations in refractive index. For OCT imaging, it is assumed that only the singly scattered eld from the sample will contribute signi cantly to the interferometric optical power. We modeled the normal biological tissue (the background) as a spatial Poisson eld of randomly distributed scattering centers, and the abnormality (the target) as a region with a di¤erent concentration of scattering centers embedded in the background. We presented the results on the detectability of abnormalities of di¤erent sizes,
منابع مشابه
Evaluation of the use of gold nanoparticle as contrast agent in electrical impedance imaging
Introduction: Electrical Impedance Tomography (EIT) is a real time and minimal invasive imaging modality for detection of lesions in tissues even when their structures show no changes. Early detection of lesion with EIT depends on difference between electrical impedance of targeted tissue and its surroundings. Therefore, finding a contrast agent for EIT that increase this diffe...
متن کاملRecent Advances in PET-MR Hybrid contrast agent
Introduction: All of the Imaging modalities have advantages and disadvantages alone. So if we want to have the best and perfect image, combining these modalities produces something we desired. PET-MR images consist of morphologic and metabolic data. MRI and PET provide high spatial and contrast resolution and high sensitivity and molecular information respectively. Hybrid PET-...
متن کاملThe Effect of Gold Nanoparticle on Electrical Impedance of Tissue on Low Frequency Ranges
Introduction: Electrical impedance of tissues on low frequencies includes useful information about functional and structural changes in tissues. This property is used in Electrical Impedance Tomography (EIT) imaging modality for the detection of lesions in tissues.Objective: The goal of this article is to study changes in electrical impedance of tissues in the presence of gold nanoparticles.Mat...
متن کاملApplications of gold nanoparticles for medical imaging
Background & Aim: Molecular imaging enables us to non-invasively visualize tissue microstructures and lesion characterization, allowing accurate diagnosis of diseases at early stages. A successful molecular imaging requires a nontoxic contrast agent with high sensitivity. Nowadays, a wide range of nanoparticles have been developed as contrast agents for medical imaging modalities. Here, we revi...
متن کاملInvestigation of acoustic properties of silica coated gold nanoparticle as contrast agent for Ultrasonography
Interoduction: Ultrasound images have often low contrast due to small differences in acoustic impedance between different tissues. Air or gas microbubbles that surrounded by membrane are most of the contrast agents in ultrasound imaging. Problems such as instability in sound pressure and inability in penetrating from the blood vessel into body tissues limited the use of microbubbles into the in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2007