Measurement and quality control issues in multiplex protein assays: a case study.

نویسندگان

  • Allison A Ellington
  • Iftikhar J Kullo
  • Kent R Bailey
  • George G Klee
چکیده

BACKGROUND Multiplex arrays are increasingly used for measuring protein biomarkers. Advantages of this approach include specimen conservation, limited sample handling, and decreased time and cost, but the challenges of optimizing assay format for each protein, selecting common dilution factors, and establishing robust quality control algorithms are substantial. Here, we use measurements of 15 protein biomarkers from a large study to illustrate processing, analytic, and quality control issues with multiplexed immunoassays. METHODS We contracted with ThermoScientific for duplicate measurements of 15 proteins in 2322 participants from a community-based cohort, a plasma control, and recombinant protein controls using 2 custom planar microarrays with 6 (panel A) or 9 (panel B) capture antibodies printed in each well. We selected constituent analytes in each panel based on endogenous concentrations and assay availability. Protocols were standardized for sample processing, storage, and freeze-thaw exposures. We analyzed data for effects of deviations from processing protocols, precision, and bias. RESULTS Measurements were within reportable ranges for each of the assays; however, concentrations for 7 of the 15 proteins were not centered on the dose-response curves. An additional freeze-thaw cycle and erroneous sample dilution for a subset of samples produced significantly different results. Measurements with large differences between duplicates were seen to cluster by analyte, plate, and participant. Conventional univariate quality control algorithms rejected many plates. Plate-specific medians of cohort and plasma control data significantly covaried, an observation important for development of alternative quality control algorithms. CONCLUSIONS Multiplex measurements present difficult challenges that require further analytical and statistical developments.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of a Multiplex RT-PCR Assay for Detection of the Causal Agents of Citrus Tristeza and Cachexia Diseases with Coamplification of Plant mRNA as an Internal Control

Background and Aims: Plant certification programs need reliable, fast, cheap and sensitive methods for detection of systemic pathogens with special interest in virus and viroid detection. Reverse transcriptase-polymerase chain reaction (RT-PCR) has been documented as an alternative assay for certification of plant propagating materials. The main object of the present study was the optimization ...

متن کامل

Analytical validation of protein-based multiplex assays: a workshop report by the NCI-FDA interagency oncology task force on molecular diagnostics.

Clinical proteomics has the potential to enable the early detection of cancer through the development of multiplex assays that can inform clinical decisions. However, there has been some uncertainty among translational researchers and developers as to the specific analytical measurement criteria needed to validate protein-based multiplex assays. To begin to address the causes of this uncertaint...

متن کامل

Protein-based multiplex assays: mock presubmissions to the US Food and Drug Administration.

As a part of ongoing efforts of the NCI-FDA Interagency Oncology Task Force subcommittee on molecular diagnostics, members of the Clinical Proteomic Technology Assessment for Cancer program of the National Cancer Institute have submitted 2 protein-based multiplex assay descriptions to the Office of In Vitro Diagnostic Device Evaluation and Safety, US Food and Drug Administration. The objective ...

متن کامل

Antibody-based protein multiplex platforms: technical and operational challenges.

BACKGROUND The measurement of multiple protein biomarkers may refine risk stratification in clinical settings. This concept has stimulated development of multiplexed immunoassay platforms that provide multiple, parallel protein measurements on the same specimen. CONTENT We provide an overview of antibody-based multiplexed immunoassay platforms and discuss technical and operational challenges....

متن کامل

Serum C-reactive protein in asthma and its ability in predicting asthma control, a case-control study

 Background: Increased serum high sensitive C-reactive protein (hs-CRP) in asthma and its association with disease severity has been investigated in many studies. This study aimed to determine serum hs-CRP status in asthma versus healthy controls and to examine its ability in predicting asthma control. Methods: Serum CRP was measured by ELISA method using a high sensitive CRP kit. Severity...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 55 6  شماره 

صفحات  -

تاریخ انتشار 2009