What is the detectability of arterial transit times in pulsed arterial spin labeling (PASL): a simulation and empirical study
نویسندگان
چکیده
Introduction: Quantitative cerebral blood flow (CBF) measurements using arterial spin labeling (ASL) are highly dependent on the arterial transit time (ATT), which corresponds to the time for blood water spins in the tagging bolus to reach the capillary exchange site. Frequently, an ASL experiment is conducted at a single inversion time (TI), which means an ATT value is assumed. The vascular geometry varies regionally, however, and ATT will vary between brain regions. Furthermore, recent evidence shows that ATT decreases in response to neuronal activation [1, 2], hypercapnia [3], and is affected by disease processes [4]. Accurate knowledge of normal ATT values and variability across the brain would therefore be useful. Regional ATT quantification is complicated, however, when using traditional multi-slice EPI readouts due to limited volume coverage and multiple excitation pulses that yield different TIs for different slices. To overcome these difficulties, we employ a multi-TI pulsed ASL (PASL) approach with a 3D GRASE readout that has demonstrated high SNR and more importantly a single excitation pulse to maintain a single, defined TI for the entire 3D volume [5]. First, we simulate the detectability of the ATT across a range of physiologically plausible values, and second, present an atlas of ATT values across the brain from a cohort of healthy individuals. The results should provide a useful reference for how ATT varies across brain regions in healthy individuals, and should be useful in clinical comparison studies where ATT may be impaired. Methods: PASL and T1-weighted anatomical data were acquired on a 3 T Siemens MRI scanner. Empirical data were from 36 healthy volunteers (15 women, 21 men, ages: 20 to 35 years) who provided written consent in accordance with the local ethics committee. The PASL imaging volume was 200 mm x 200 mm x 96 mm (half kz-space coverage; 64 x 64 x 24 matrix size; voxel dimensions: 3.1 x 3.1 x 5.0 mm), TR/TE = 3150 / 40.6 ms, TI=[400:200:2400ms], background suppression, total acquisition time: 11 min 33 s. A two-parameter (CBF and ATT), single compartment ASL model was used to fit the multi-TI data for every voxel using least squares fitting in Matlab. Zstats were used to quantify the confidence in fit estimates at each voxel; e.g. for CBF Z-statsCBF = μCBF/σCBF. ATT maps were converted to standard space (MNI) and mean and variance maps were used to create an ATT atlas. ATT values were computed for the different lobes and for males and females using the Oxford-Harvard brain atlas. Simulations of PASL were performed using the identical set of TI values as the empirical data. Simulated CBF levels were kept constant while the ATT values ranged from 0.3 to 2.4 s. Signal-to-noise ratios for the kinetic curves were assumed based on the empirical data. Noise was assumed to be Gaussian and added in increasing increments to simulate a range of SNR scenarios. 500 simulations were performed at each simulated ATT and at each noise level. Results: Plotting the simulated Z-stats for ATT or CBF as a function of the simulated ATT produced a consistent pattern (Fig. 1top). ATT Z-stats showed a quadratic dependence on the simulated ATT, while CBF Z-stats showed a decreasing linear trend. The simulated data agreed well with empirical data (Fig. 1-bottom). Figure 2 and the table show the natural variation of ATT across the brain. Women were found to have a significantly reduced ATT compared to men (P<0.003).
منابع مشابه
Comparison of arterial transit times estimated using FEAST and LL-FAIR
Introduction Arterial transit time is a critical parameter for calculating cerebral blood flow (CBF) using arterial spin labeling (ASL). Arterial transit time is also a novel physiological parameter that is uniquely measured by ASL and may have independent clinical significance for detecting CBF that is maintained through collateral flow sources. Most ASL experiments acquire data at a single de...
متن کاملPerfusion: ASL Basics and Analysis
WHO: Newcomers to the Arterial Spin Labeling (ASL) perfusion field. WHAT: The basic ASL acquisition sequences will be introduced and it will be explained how to subsequently process the data. OUTLINE: 1. The acquisition a. Spatial labeling (PASL) versus b. Temporal labeling (CASL, pCASL) c. Background suppression 2. Basic blood flow kinetics a. Blood and tissue compartments b. Scaling parameter...
متن کاملMeasurement of brain perfusion in newborns: Pulsed arterial spin labeling (PASL) versus pseudo-continuous arterial spin labeling (pCASL)
BACKGROUND Arterial spin labeling (ASL) perfusion-weighted imaging (PWI) by magnetic resonance imaging (MRI) has been shown to be useful for identifying asphyxiated newborns at risk of developing brain injury, whether or not therapeutic hypothermia was administered. However, this technique has been only rarely used in newborns until now, because of the challenges to obtain sufficient signal-to-...
متن کاملPractical Investigation of pseudo-Continuous Arterial Spin Labeling (pCASL) feasibility at very high field (11.75T)
Introduction: A new strategy for continuous arterial spin labeling (CASL) using pulsed RF and gradient fields and referred as pseudo-continuous ASL (pCASL), has recently been developed and optimized for human studies at 3T. Promising results demonstrated that pCASL combines advantages of pulsed ASL (PASL) and CASL by providing good labeling efficiency, high Signal to Noise (SNR) and multi-slice...
متن کاملSingle Coil Amplitude Modulated Continuous Arterial Spin Labeling Perfusion MR at 3.0 Tesla
J. Wang, Y. Zhang, R. L. Wolf, A. C. Roc, D. C. Alsop, J. A. Detre Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States, Department of Neurology, University of Pennsylvania, Philadelphia, PA, United States, Department of Radiology, Harvard Medical School, Boston, MA, United States Introduction Recently technical developments demonstrated a greater than 2-fold SNR...