On the origin of fluorescence emission in optically non-linear DCNP crystals.

نویسندگان

  • O Morawski
  • A L Sobolewski
  • B Kozankiewicz
  • L Sznitko
  • A Miniewicz
چکیده

We study absorption and emission spectra of optically nonlinear single crystals of 3-(1,1-dicyanoethenyl)-1-phenyl-4,5-dihydro-1H-pyrazole (DCNP) at 5 K. We argue that fluorescence has a complex origin, it is emitted from the excitonic band, with the bottom at ∼18,115 cm(-1), and from trap states, and the two main traps have depths of ∼875 and ∼2465 cm(-1). The excitonic origin of the emission is confirmed by the vibrational structure of fluorescence, closely resembling vibrations observed in the Raman scattering spectrum (recorded for DCNP crystals at 295 K) and by very short decay time of the excitonic emission, as a consequence of exciton migration and trapping at deep traps.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spectral Separation of Quantum Dots within Tissue Equivalent Phantom Using Linear Unmixing Methods in Multispectral Fluorescence Reflectance Imaging

Introduction Non-invasive Fluorescent Reflectance Imaging (FRI) is used for accessing physiological and molecular processes in biological media. The aim of this article is to separate the overlapping emission spectra of quantum dots within tissue-equivalent phantom using SVD, Jacobi SVD, and NMF methods in the FRI mode. Materials and Methods In this article, a tissue-like phantom and an optical...

متن کامل

Different Aspects of Ultra-weak Photon Emissions: A Review Article

All biological samples emit ultra-low intensity light without any external stimulation. Recently, scientific communities have paid particular attention to this phenomenon, known as ultra-weak photon emission (UPE). UPE has been introduced in the literature as an alternative for biophoton, low-level chemiluminescence and ultra-weak bioluminescence, while it differs from ordinary bioluminescence,...

متن کامل

Coupling Second-Order Excitation-Emission Spectrofluorimetric Data with Standard Addition method to Quantify Carvedilol in Real Samples

Prediction using pure standards is expected to be biased whenever the slope of the calibration is affected by the presence of sample matrix. Moreover, in the presence of unknown spectral interferents, first-order algorithms like partial least squares cannot be used. In this study, a method for determination of carvedilol (CAR) in tablet and urine samples is proposed by excitation-emission fluor...

متن کامل

Comparative Studies of High Contrast Fluorescence Imaging Efficiency of Silica-coated CdSe Quantum Dots with Green and Red Emission

Herein we report the possibility of using green and red emitting silica-coated cadmium selenide (CdSe) quantum dots (QDs) for remarkable stem and cancer cellular imaging, efficient cellular uptake and fluorescence imaging of semi and ultra-thin sections of tumor for in vivo tumor targeted imaging applications. The comparative studies of high contrast cellular imaging behaviours of the silica-co...

متن کامل

Development of a Simple and Sensitive Terbium Sensitized Fluorescence Method for Determination of Epinephrine and Norepinephrine in Serum

     A simple, rapid, selective and highly sensitive fluorimetric method for determination of two catecholamines, i.e. norepinephrine (NE) and epinephrine (EP), in serum samples was developed. The method is based on the fluorescence sensitization of terbium (Tb3+) by complexation with both catecholamines in the presence of lanthanum (La3+), as a co-cation, and in a Na...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physical chemistry chemical physics : PCCP

دوره 16 48  شماره 

صفحات  -

تاریخ انتشار 2014