Simultaneous measurement of in-plane and out-of-plane displacement fields in scattering media using phase-contrast spectral optical coherence tomography.

نویسندگان

  • Manuel H De la Torre Ibarra
  • Pablo D Ruiz
  • Jonathan M Huntley
چکیده

The use of phase-contrast spectral optical coherence tomography to measure two orthogonal displacement components on a slice within a scattering medium is demonstrated. This is achieved by combining sequential oblique illumination of the object and recording two interferograms before plus two after the deformation. The proposed technique is illustrated with results from a sample undergoing simple shear. Depth-resolved out-of-plane and in-plane sensitivities of 0.14 and 4.2 microm per fringe are demonstrated up to a depth of 400 microm in a water-based polymer.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous measurement of in-plane and out-of-plane displacement elds in scattering media using phase-contrast spectral optical coherence tomography

The use of phase contrast spectral optical coherence tomography to measure two orthogonal displacement components on a slice within a scattering medium is demonstrated. This is achieved by combining sequential oblique illumination of the object and recording two interferograms before plus two after the deformation. The proposed technique is illustrated with results from a sample undergoing simp...

متن کامل

بررسی پایایی و تکرار پذیری دستگاه Spectral domain optical coherence tomography در اندازه گیری ضخامت ماکولا در چشمهای طبیعی قبل و بعد از گشاد کردن مردمک

Background: optical coherence tomography is one of the most valuable imaging techniques in the evaluation of macula. Objective: to investigate the repeatability and reproducibility of OCT  in measuring the macular thickness in normal eyes before and after pupil dilation. Methods: A total of 44 eyes were enrolled. All subjects underwent macular thickness measurement using the Cirrus SD-OCT ma...

متن کامل

Self-referenced Doppler optical coherence tomography.

Doppler optical coherence tomography (DOCT) allows simultaneous micrometer-scale resolution cross-sectional imaging of tissue structure and blood flow. We demonstrate a fiber-optic polarization-diversity-based differential phase contrast DOCT system as a method to perform self-referenced velocimetry in highly scattering media. Using this strategy, we reduced common-mode interferometer noise to ...

متن کامل

اصلاح توام نقص ابیراهی لنز دوربین و خطای خروج از مرکز تصویر با بهره‌گیری از مدل اصلاح شده زرنیک

Reduction of the quality of the image formed by an optical system is a function of different parameters such as lens aberrations, CCD digitization errors, and the errors of system assembling. Assembling errors usually consist of two types: 1) the prism error, which is the error of non-orthogonality of the optical axis and the image plane 2) the de-centering error, which is error of not passing ...

متن کامل

Retinal Ganglion Cell Complex in Alzheimer Disease: Comparing Ganglion Cell Complex and Central Macular Thickness in Alzheimer Disease and Healthy Subjects Using Spectral Domain-Optical Coherence Tomography

Introduction: Alzheimer disease (AD) is the most common form of dementia worldwide. The modalities to diagnose AD are generally expensive and limited. Both the central nervous system (CNS) and the retina are derived from the cranial neural crest; therefore, changes in retinal layers may reflect changes in the CNS tissue. Optical coherence tomography (OCT) machine can show delicate retinal layer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics letters

دوره 34 6  شماره 

صفحات  -

تاریخ انتشار 2009