Evaluation of real-time PCR laboratory-developed tests using analyte-specific reagents for cytomegalovirus quantification.

نویسندگان

  • Angela M Caliendo
  • Jessica Ingersoll
  • Andrea M Fox-Canale
  • Sabine Pargman
  • Tameka Bythwood
  • Mary K Hayden
  • James W Bremer
  • Nell S Lurain
چکیده

Viral load testing for cytomegalovirus (CMV) has become the standard for the diagnosis of infection and monitoring of therapy at many transplant centers. However, no viral load test has been approved by the FDA. Therefore, many laboratories rely on laboratory-developed assays. This study evaluated the performance characteristics of two real-time PCR tests developed using the artus CMV analyte-specific reagents (ASRs). One version is distributed by Abbott Molecular and the other by QIAGEN. For plasma specimens, the Abbott test had a limit of detection of 2.3 log10 copies/ml and a linear range up to at least 6.0 log10 copies/ml. Comparison of plasma viral loads using the Abbott test and the Roche Amplicor Monitor test showed a mean difference of -0.012 log10 copies/ml. In addition, the Abbott test viral loads correlated with the Digene Hybrid Capture assay ratios. Viral loads obtained from plasma specimens tested by the Abbott and QIAGEN tests were in very close agreement (mean difference, 0.144 log10 copies/ml). When the QIAGEN test was evaluated with the QIAGEN, MagNA Pure, and easyMAG extraction methods, the viral loads for all three methods were within 0.370 log10 copies/ml. Thus, there is good agreement between viral loads obtained by the different tests using the same extraction method or by the same test using different extraction methods. The availability of real-time PCR ASRs provides additional reagents that can be used for CMV viral load testing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Digene Hybrid Capture System Cytomegalovirus (CMV) DNA (version 2.0), Roche CMV UL54 analyte-specific reagent, and QIAGEN RealArt CMV LightCycler PCR reagent tests using AcroMetrix OptiQuant CMV DNA quantification panels and specimens from allogeneic-stem-cell transplant recipients.

The Digene Hybrid Capture system cytomegalovirus (CMV) DNA (version 2.0), Roche CMV UL54 analyte-specific reagent, and QIAGEN RealArt CMV LightCycler PCR reagent tests were compared using whole-virus standards and plasma specimens collected from allogeneic-stem-cell transplant recipients. PCR assays showed better speed, sensitivity, and specificity.

متن کامل

Comparison of six real-time PCR assays for qualitative detection of cytomegalovirus in clinical specimens.

In this study, we compared the performance of six real-time PCR assays for the qualitative detection of cytomegalovirus (CMV) in clinical samples other than plasma. Two hundred specimens (respiratory [n = 72], urine [n = 67], cerebrospinal fluid [CSF] [n = 25], tissue [n = 18], amniotic fluid [n = 10], and bone marrow [n = 8]) submitted for routine testing by CMV real-time PCR analyte-specific ...

متن کامل

Optimization of a laboratory-developed test utilizing roche analyte-specific reagents for detection of Staphylococcus aureus, methicillin-resistant S. aureus, and vancomycin-resistant Enterococcus species.

Nasal and perianal swab specimens were tested for detection of Staphylococcus aureus and vancomycin-resistant Enterococcus species (VRE) using a laboratory-developed real-time PCR test and microbiological cultures. The real-time PCR and culture results for S. aureus were similar. PCR had adequate sensitivity, but culture was more specific for the detection of VRE.

متن کامل

Development of qRT-PCR Test for Quantification of Rubella Virus in Commercially Available Vaccines

vaccines is considered as a critical point and in-process of quality control (IPQC) test of vaccine production. Rapid tests, like real time PCR, are more appropriated when the production occurs at industrial scale because of the amounts of starting materials and the excess of consumed time required. In the current study, a real-time quantitative reverse transcription-polymerase chain reaction...

متن کامل

Precision across the analytical measuring range of a quantitative real-time PCR assay for cytomegalovirus detection among three clinical laboratories.

This study measured the precision of a quantitative laboratory-developed real-time PCR test for cytomegalovirus performed at three different clinical laboratories that use the same methodology. The overall standard deviation (adjusted for analyte level) was 0.18 log(10) copies/ml, and there was no significant relationship between standard deviation and analytical measuring range.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 45 6  شماره 

صفحات  -

تاریخ انتشار 2007