Variability between experts in defining the edge and area of the optic nerve head.

نویسندگان

  • S Alayon
  • M Gonzalez de la Rosa
  • F J Fumero
  • J F Sigut Saavedra
  • J L Sanchez
چکیده

OBJECTIVE Estimation of the error rate in the subjective determination of the optic nerve head edge and area. METHOD 1) 169 images of optic nerve disc were evaluated by five experts for the defining of the edges in 8 positions (every 45°). 2) The estimated areas of 26 cases were compared with the measurements of the Cirrus Optical Coherence Tomography (OCT-Cirrus). RESULTS 1) The mean variation of the estimated radius was ±5.2%, with no significant differences between sectors. Specific differences were found between the 5 experts (P <.001), each one compared with the others. 2) The disc area measured by the OCT-Cirros was 1.78 mm² (SD =0.27). The results corresponding to the experts who detected smaller areas were better correlated to the area detected by the OCT-Cirrus (r=0.77-0.88) than the results corresponding to larger areas (r =0.61-0.69) (P <.05 in extreme cases). CONCLUSIONS There are specific patterns in each expert for defining the disc edges and involve 20% variation in the estimation of the optic nerve area. The experts who detected smaller areas have a higher agreement with the objective method used. A web tool is proposed for self-assessment and training in this task.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Applications of Optical Coherence Tomography in Ophthalmology

Assessment of the peripapillary nerve fiber layer and macular thickness can be determined in ophthalmology using optical coherence tomography (OCT). Decreased nerve fiber layer thickness and macular ganglion cell thickness in optic nerve ischemia have been correlated with visual field loss. OCT allows deep optic nerve head evaluation which helps understand pathophysiology of diseases.  Furtherm...

متن کامل

Variability across the optic nerve head in scanning laser tomography.

AIM To characterise measurement variability in scanning laser tomography of the optic nerve head. METHODS 21 normal and 21 glaucoma subjects underwent same and separate day test-retest Heidelberg retina tomograph imaging by the same and different operators. RESULTS Rim area was most reproducible among parameters. Its variability tended to be highest temporally and increased (p<0.05) with te...

متن کامل

Effect of scuba-diving on optic nerve and sheath diameters

  Background :There is not any data available about the effect of high bar pressure condition on intracranial pressure. In this study, the effect of diving on the optic nerve and sheath diameters as non-invasive markers of intracranial pressure has been investigated.   Methods : Twenty professional male divers from twenty one volunteers were chosen for this cross-sectional study. Only one perso...

متن کامل

Three Dimensional Ultrasonography of the Eye and Measurement of Optical Nerve Sheet Diameter in Dog

Objective-  To determine the possibility of three-dimensional ultrasonography (3DUS) and measurement of optical nerve sheet by this method. Design- Descriptive study. Animals- 10 mixed normal dogs (5males, 5 females), age 1-1.5 year, and weighting 15±5 kg Procedure- 3D ultrasounds of the eyes were evaluated and the normal optical nerves in 3DUS images were measured using Volouson 730 pro....

متن کامل

Gonioscopic Features in Patients with Acute and Chronic Angle-Closure Glaucoma

Background: A number of ocular biometric parameters, iris hiotologic and anatomic characters have been suggested as inciting factors for converting patients with narrow angle to angle-closure glaucoma. This study was conducted to determine if there was any goniscopic difference between patients with acute angle-closure glaucoma (AACG) and chronic angle-closure glaucoma (CACG). Methods: ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Archivos de la Sociedad Espanola de Oftalmologia

دوره 88 5  شماره 

صفحات  -

تاریخ انتشار 2013