BACKGROUND Combination of riboflavin/UVA cross-linking (CXL) and excimer laser ablation is a promising therapy for treating corneal ectasia. The cornea is strengthened by cross-linking, while the irregular astigmatism is reduced by laser ablation. This study aims to compare the efficacy of excimer laser ablation on porcine corneas with and without cross-linking. METHODS AND FINDINGS The porcine cornea was de-epithelialized and treated with 0.1% riboflavin solution for 30 minutes. A half of the cornea was exposed to UVA-radiation for another 30 minutes while the controlled half of the cornea was protected from the UVA using a metal shield. Photo therapeutic keratectomy (PTK) was then performed on the central cornea. Corneal thickness of 5 paired locations on the horizontal line, ± 0.5, ± 1.0, ± 1.5, ± 2.0, and ± 2.5 mm from the central spot, were measured using optical coherence tomography prior to and after PTK. The ablation depth was then determined by the corneal thickness. There was a 9% difference (P<0.001) in the overall ablation depth between the CXL-half corneas (158 ± 22 µm) and the control-half corneas (174 ± 26 µm). The ablation depths of all 5 correspondent locations on the CXL-half were significantly smaller (P<0.001). CONCLUSION The efficacy of the laser ablation seems to be lower in cross-linked cornea. Current ablation algorithms may need to be modified for cross-linked corneas.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of the excimer laser ablation rate in previously cross-linked corneas.

PURPOSE To evaluate the need for and quantify the extent of nomogram adjustments to compensate for potential changes in the amount of effective corneal stroma ablated in previously cross-linked corneas. METHODS Ex vivo porcine corneas were divided into two groups (the corneal cross-linking [CXL] group, n = 30; and the control group, n = 3): these experimental corneas underwent CXL including d...

متن کامل

Unscheduled DNA synthesis following excimer laser ablation of the cornea in vivo.

The amount of unscheduled DNA synthesis (UDS) produced in the cells adjacent to excimer laser ablations in the cornea was compared for 193-nm and 248-nm laser wavelengths. UDS is interpreted to indicate the process of excision repair of pyrimidine dimers formed in DNA. 193-nm laser ablation did not produce a statistically significant difference in the amount of UDS as compared to a negative con...

متن کامل

308-nm excimer laser plus topical calcipotriol in the treatment of vitiligo; A single blind randomized clinical study

Background: There is a large variety of therapeutic agents for the treatment of vitiligo, but it still remains a challenge. Narrow-band UVB phototherapy and 308-nm excimer laser have been shown to be safe and effective for the treatment of vitiligo. Topical calcipotriol has recently been reported to enhance the efficacy of phototherapy, especially 8-methoxypsoralen plus UVA (PUVA). The goal of ...

متن کامل

Influence of corneal collagen crosslinking with riboflavin and ultraviolet-a irradiation on excimer laser surgery.

PURPOSE Riboflavin/ultraviolet A (UVA) cross-linking (CXL) of corneal collagen is a novel method of stabilizing corneal mechanical properties and preventing progression of keratectasias. This study was conducted to investigate whether CXL influences ablation rate, flap thickness, and refractive results of excimer laser procedures ex vivo. METHODS Corneal epithelium was removed from enucleated...

متن کامل

Histological comparison of corneal ablation with Er:YAG laser, Nd:YAG optical parametric oscillator, and excimer laser.

PURPOSE To use histological techniques to assess and compare the ablation depth, local damage, and surface quality of corneal ablations by a Q-switched Er:YAG laser, an optical parametric oscillator laser at 2.94 microm, a long pulse Er:YAG laser, and a 193-nm excimer laser. METHODS Human cadaver eyes and in vivo cat eyes were treated with a 6.0-mm diameter, 30-microm-deep phototherapeutic ke...