Estimating myocardial perfusion from dynamic contrast-enhanced CMR with a model-independent deconvolution method
نویسندگان
چکیده
BACKGROUND Model-independent analysis with B-spline regularization has been used to quantify myocardial blood flow (perfusion) in dynamic contrast-enhanced cardiovascular magnetic resonance (CMR) studies. However, the model-independent approach has not been extensively evaluated to determine how the contrast-to-noise ratio between blood and tissue enhancement affects estimates of myocardial perfusion and the degree to which the regularization is dependent on the noise in the measured enhancement data. We investigated these questions with a model-independent analysis method that uses iterative minimization and a temporal smoothness regularizer. Perfusion estimates using this method were compared to results from dynamic 13N-ammonia PET. RESULTS An iterative model-independent analysis method was developed and tested to estimate regional and pixelwise myocardial perfusion in five normal subjects imaged with a saturation recovery turboFLASH sequence at 3 T CMR. Estimates of myocardial perfusion using model-independent analysis are dependent on the choice of the regularization weight parameter, which increases nonlinearly to handle large decreases in the contrast-to-noise ratio of the measured tissue enhancement data. Quantitative perfusion estimates in five subjects imaged with 3 T CMR were 1.1 +/- 0.8 ml/min/g at rest and 3.1 +/- 1.7 ml/min/g at adenosine stress. The perfusion estimates correlated with dynamic 13N-ammonia PET (y = 0.90x + 0.24, r = 0.85) and were similar to results from other validated CMR studies. CONCLUSION This work shows that a model-independent analysis method that uses iterative minimization and temporal regularization can be used to quantify myocardial perfusion with dynamic contrast-enhanced perfusion CMR. Results from this method are robust to choices in the regularization weight parameter over relatively large ranges in the contrast-to-noise ratio of the tissue enhancement data.
منابع مشابه
Hyperemic stress myocardial perfusion cardiovascular magnetic resonance in mice at 3 Tesla: initial experience and validation against microspheres
BACKGROUND Dynamic first pass contrast-enhanced myocardial perfusion is the standard CMR method for the estimation of myocardial blood flow (MBF) and MBF reserve in man, but it is challenging in rodents because of the high temporal and spatial resolution requirements. Hyperemic first pass myocardial perfusion CMR during vasodilator stress in mice has not been reported. METHODS Five C57BL/6 J ...
متن کاملFully automated pixel-wise myocardial blood flow quantification with first-pass perfusion CMR
Methods Rest and adenosine stress perfusion imaging was performed on 17 normal volunteers. A saturation recovery SSFP dual-sequence technique was used to acquire three myocardial slices and an arterial input function (AIF) image series. A proton-density weighted image was acquired at the beginning of each series. Fully quantitative perfusion pixel maps were generated by an automated processing ...
متن کاملThe relationship between spatial resolution levels and quantitative myocardial perfusion
Background Dynamic contrast enhanced cardiovascular magnetic resonance imaging (DCE-CMR) allows for high-resolution analysis of myocardial perfusion by preserving important spatial information. However high resolution perfusion quantification suffers from the poor signal-to-noise ratio (SNR) of voxel-based data. Previously spatial averaging (segmental or sub-segmental analysis) has been used to...
متن کاملA quantitative pixel-wise measurement of myocardial blood flow by contrast-enhanced first-pass CMR perfusion imaging: microsphere validation in dogs and feasibility study in humans.
OBJECTIVES The aim of this study was to evaluate fully quantitative myocardial blood flow (MBF) at a pixel level based on contrast-enhanced first-pass cardiac magnetic resonance (CMR) imaging in dogs and in patients. BACKGROUND Microspheres can quantify MBF in subgram regions of interest, but CMR perfusion imaging may be able to quantify MBF and differentiate blood flow at a much higher resol...
متن کاملEvaluation of model-independent deconvolution techniques to estimate lung parenchymal perfusion
Dynamic contrast enhanced (DCE) MRI has become a useful technique for measuring perfusion in many applications. !e theoretical basis for perfusion quanti"cation is the central volume principle, which requires deconvolution of the measured arterial input and tissue concentration curves to derive a residue function (R) and mean blood perfusion. Deconvolution methods generally di#er in assumptions...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of Cardiovascular Magnetic Resonance
دوره 10 شماره
صفحات -
تاریخ انتشار 2008