Rate nephelometric assay of serum lipoprotein(a).

نویسندگان

  • P Gillery
  • P Arthuis
  • C Cuperlier
  • R Circaud
چکیده

This nephelometric assay of serum lipoprotein(a) [Lp(a)] is characterized by the use of a specific antibody to generate a high rate of light-scatter formation and the elimination of nonspecific reactions from serum samples by diluting samples in phosphate-buffered saline containing polymer enhancer polyethylene glycol (PEG), 40 g/L, and detergent before the assay. We reacted 100 microL of sixfold-diluted serum in 500 microL of buffer containing PEG with 42 microL of pure polyclonal rabbit antiserum (Dakopatts) directed against human Lp(a) and monitored the reaction by rate nephelometry with the Array Protein System nephelometer (Beckman). The standard curve for the reaction was linear in the Lp(a) range 10-1280 mg/L; antigen excess occurred between 1300 and 1400 mg/L. Calibration was performed with serial dilutions of a standard serum. Precision studies showed within-run and between-run CVs of < 2.1% and 6.9%, respectively. The nephelometric results (y) for 100 serum samples were highly correlated with those obtained by radial immunodiffusion (x) calibrated with the same materials: y = 1.07 (+/- 0.03) x - 16.2 (+/- 8.1) mg/L (r = 0.974, P < 0.001). Storing serum for 3 weeks at 4 degrees C or 3 months at -80 degrees C did not affect the results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitation of beta-lipoprotein in cord serum by rate nephelometric immunoassay: a potential screening test for familial hypercholesterolemia.

We measured beta-lipoprotein in 232 cord sera by rate nephelometry and compared the results with those obtained by electroimmunoassay. The mean (mean +/- two standard deviations) was 544 (293-1009) mg/L by rate nephelometry and 503 (265-955) mg/L by electroimmunoassay. The between-assay correlation coefficient was 0.891. Between-run coefficients of variation were 3.5-4.4% for nephelometry and 1...

متن کامل

Three immunoassay methods evaluated for quantifying prealbumin (transthyretin) in serum.

We developed an immunoturbidimetric assay for prealbumin on the Cobas Bio centrifugal analyzer and compared results from this assay with those from a rate nephelometric assay (Beckman Instruments Inc.) and a radial immunodiffusion kit (Behring Diagnostics). All three assays were evaluated for precision, linearity, and correlation to each other for analysis of sera from pediatric patients. All a...

متن کامل

A new High Sensitive Functional Nephelometrical Assay for Assaying C- reactive protein in Serum Based on Phosphocholine Interaction

C-reactive protein (CRP) is able to bind phosphocholine in the presence of calcium ions. According to a previous functional property of CRP, we tried to develop an affordable and cheap high sensitive nephelometric CRP assay using soy oil. Serum samples were measured by Nephelometer BNII (Siemens), by mixing the serum with diluted soy oil emulsion (Intralipid ® 20%) and Tris-calcium buffer (PH 7...

متن کامل

Evaluation of a nephelometric assay for haptoglobin and its clinical usefulness.

Serum haptoglobin has been advocated as an indicator of intravascular hemolysis. We have evaluated a nephelometric determination of serum haptoglobin. The assay is sensitive and exhibits within-run precision in the range of 2.5-7.4% coefficient of variation (CV) and between-run precision of 7.0% (CV). In addition, when haptoglobin values determined with the nephelometric assay were compared wit...

متن کامل

A new high-sensitive nephelometric method for assaying serum C-reactive protein based on phosphocholine interaction.

BACKGROUND The measurement of C-reactive protein (CRP) concentrations has been of interest as a classical marker of acute phase response; in addition, it has been of particular interest in cardiovascular risk stratification where high-sensitive measurements are necessary. Since CRP is able to bind phospholipids (mainly phosphocholine) in the presence of calcium ions, we explored the possibiliti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 39 3  شماره 

صفحات  -

تاریخ انتشار 1993