Intra-voxel incoherent motion MRI of the living human foetus: technique and test–retest repeatability
نویسندگان
چکیده
Background: Our purpose was to test the within-subject (test–retest) reproducibility of the perfusion fraction, diffusion coefficient, and pseudo-diffusion coefficient measurements in various foetus organs and in the placenta based on the intra-voxel incoherent motion (IVIM) principle. Methods: In utero diffusion-weighted IVIM magnetic resonance imaging (MRI) was performed in 15 pregnant women (pregnancy age 21–36 weeks) on 1.5-T and 3.0-T clinical scanners with b-factors in the range of 0–900 s/ mm in 16 steps. A bi-exponential model was fitted on the volume-averaged diffusion values. Perfusion fraction (f), diffusion coefficient (d), and pseudo-diffusion coefficient (D*) were calculated. Within-subject reproducibility was evaluated as test–retest variability (VAR %) of the IVIM parameters in the foetal frontal cortex, frontal white matter, cerebellum, lungs, kidneys, liver, and in the placenta. Results: For the foetal lungs, liver and the placenta, test–retest variability was in the range of 14–20% for f, 12–14% for d, and 17–25% for D*. The diffusion coefficients of the investigated brain regions were moderately to highly reproducible (VAR 5–15%). However, f and D* showed inferior reproducibility compared to corresponding measures for the lungs, liver, and placenta. The IVIM parameters of the foetal kidney were revealed to be highly variable across scans. Conclusions: IVIM MRI potentially provides a novel method for examining microvascular perfusion and diffusion in the developing human foetus. However, reproducibility of perfusion and diffusion parameters depends greatly upon data quality, foetal and maternal movements, and foetal-specific image post-processing.
منابع مشابه
Rectal cancer
The aim of this study was to evaluate the short-term test-retest reproducibility of diffusion-weighted magnetic resonance imaging (DW-MRI) parameters of rectal cancer with 3.0T MRI.Twenty-six patients with rectal cancer underwent MRI, including diffusion-weighted imaging with 8 b values. Apparent diffusion coefficient (ADC) and intravoxel incoherent motion (IVIM) parameters (D, pure diffusion; ...
متن کاملTest-retest repeatability of human speech biomarkers from static and real-time dynamic magnetic resonance imaging.
Static anatomical and real-time dynamic magnetic resonance imaging (RT-MRI) of the upper airway is a valuable method for studying speech production in research and clinical settings. The test-retest repeatability of quantitative imaging biomarkers is an important parameter, since it limits the effect sizes and intragroup differences that can be studied. Therefore, this study aims to present a f...
متن کاملSpatially Constrained Probability Distribution Model of Incoherent Motion (spim) Improves Longitudinal Reproducibility of Quantitative Diffusion Weighted Mri
Purpose: Diffusion-weighted MRI (DW-MRI) of the body is a non-invasive imaging technique that enables characterization of tissue microenvironments through measurement of variations in the mobility of water molecules due to cellularity, cell membrane integrity, and compartment they are located. Quantitative DW-MRI has a well-established role in the detection, characterization and follow-up of a ...
متن کاملIntravoxel incoherent motion diffusion‐weighted MRI during chemoradiation therapy to characterize and monitor treatment response in human papillomavirus head and neck squamous cell carcinoma
PURPOSE Characterize and monitor treatment response in human papillomavirus (HPV) head and neck squamous cell carcinoma (HNSCC) using intra-treatment (intra-TX) imaging metrics derived from intravoxel incoherent motion (IVIM) diffusion-weighted magnetic resonance imaging (DW-MRI). MATERIALS AND METHODS Thirty-four (30 HPV positive [+] and 4 HPV negative [-]) HNSCC patients underwent a total o...
متن کاملReliability of MRI-derived cortical and subcortical morphometric measures: Effects of pulse sequence, voxel geometry, and parallel imaging
Advances in magnetic resonance imaging (MRI) have contributed greatly to the study of neurodegenerative processes, psychiatric disorders, and normal human development, but the effect of such improvements on the reliability of downstream morphometric measures has not been extensively studied. We examined how MRI-derived neurostructural measures are affected by three technological advancements: p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2017