Simultaneous MV-kV imaging for intrafractional motion management during volumetric-modulated arc therapy delivery.

نویسندگان

  • Margie A Hunt
  • Mark Sonnick
  • Hai Pham
  • Rajesh Regmi
  • Jian-ping Xiong
  • Daniel Morf
  • Gig S Mageras
  • Michael Zelefsky
  • Pengpeng Zhang
چکیده

The purpose of this study was to evaluate the accuracy and clinical feasibility of a motion monitoring method employing simultaneously acquired MV and kV images during volumetric-modulated arc therapy (VMAT). Short-arc digital tomosynthesis (SA-DTS) is used to improve the quality of the MV images that are then combined with orthogonally acquired kV images to assess 3D motion. An anthropomorphic phantom with implanted gold seeds was used to assess accuracy of the method under static, typical prostatic, and respiratory motion scenarios. Automatic registra-tion of kV images and single MV frames or MV SA-DTS reconstructed with arc lengths from 2° to 7° with the appropriate reference fiducial template images was performed using special purpose-built software. Clinical feasibility was evaluated by retrospectively analyzing images acquired over four or five sessions for each of three patients undergoing hypofractionated prostate radiotherapy. The standard deviation of the registration error in phantom using MV SA-DTS was similar to single MV images for the static and prostate motion scenarios (σ = 0.25 mm). Under respiratory motion conditions, the standard deviation of the registration error increased to 0.7mm and 1.7 mm for single MV and MV SA-DTS, respectively. Registration failures were observed with the respiratory scenario only and were due to motion-induced fiducial blurring. For the three patients studied, the mean and standard deviation of the difference between automatic registration using 4° MV SA-DTS and manual registration using single MV images results was 0.07±0.52mm. The MV SA-DTS results in patients were, on average, superior to single-frame MV by nearly 1 mm - significantly more than what was observed in phantom. The best MV SA-DTS results were observed with arc lengths of 3° to 4°. Registration failures in patients using MV SA-DTS were primarily due to blockage of the gold seeds by the MLC. The failure rate varied from 2% to 16%. Combined MV SA-DTS and kV imaging is feasible for intratreatment motion monitoring during VMAT of anatomic sites where limited motion is expected, and improves registration accuracy compared to single MV/kV frames. To create a clinically robust technique, further improvements to ensure visualization of fiducials at the desired control points without degradation of the treatment plan are needed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Phase-matched Digital Tomosynthesis (DTS) Imaging for Simultaneous Target Verification during Volumetric Modulated Arc Therapy (VMAT) Treatment

Innovation and Impact: Currently, very few target verification techniques are available during VMAT treatment. kV/MV imaging provides 2D anatomical information but not tomographic information. GPS tracking like Calypso (Calypso, Seattle, WA) is also available, but requires invasive procedures and provides no anatomical information. To achieve more accurate and non-invasive target verification s...

متن کامل

A megavoltage scatter correction technique for cone-beam CT images acquired during VMAT delivery.

Kilovoltage cone-beam CT (kV CBCT) can be acquired during the delivery of volumetric modulated arc therapy (VMAT), in order to obtain an image of the patient during treatment. However, the quality of such CBCTs is degraded by megavoltage (MV) scatter from the treatment beam onto the imaging panel. The objective of this paper is to introduce a novel MV scatter correction method for simultaneous ...

متن کامل

Prostate Intrafraction Motion Assessed by Simultaneous Kv

PROSTATE INTRAFRACTION MOTION ASSESSED BY SIMULTANEOUS KV FLUOROSCOPY AT MV DELIVERY by JUSTUS D. ADAMSON August 2009 Co-Advisor: Dr. Qiuwen Wu Co-Advisor: Dr. Jay Burmeister Major: Medical Physics Degree: Doctor of Philosophy Purpose: To investigate the use of a gantry mounted kV imager for prostate intrafraction motion measurement during simultaneous dose delivery. Materials & Methods: We dev...

متن کامل

Initial experience with intra‐fraction motion monitoring using Calypso guided volumetric modulated arc therapy for definitive prostate cancer treatment

INTRODUCTION Accurate delivery of radiation while reducing dose to organs at risk is essential in prostate treatment. The Calypso motion management system detects and corrects both inter- and intra-fraction motion which offers potential benefits over standard alignment to fiducial markers. The aims of this study were to implement Calypso with Dynamic Edge™ gating and to assess both the motion s...

متن کامل

Real-time tumor tracking during VMAT radiotherapy treatments based on 2D/3D registration using CBCT projections

Rotational radiotherapy treatments such as volumetric modulated arc therapy (VMAT) can have superior overall quality while having shorter delivery time with respect to conventional intensity modulated radiotherapy (IMRT). As with conventional treatments, intrafractional tumor motion is a major source of uncertainty in dose application. To ensure full tumor coverage the planning target volume (P...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of applied clinical medical physics

دوره 17 2  شماره 

صفحات  -

تاریخ انتشار 2016