Tedisamil increases coherence during ventricular fibrillation and decreases defibrillation energy requirements.

نویسندگان

  • P Dorian
  • D Newman
چکیده

INTRODUCTION Drugs which primarily prolong cardiac refractoriness decrease defibrillation voltage and energy requirements in animals and man. The effect of such drugs on ventricular fibrillation itself is not well understood. We hypothesized that tedisamil, an investigational antiarrhythmic drug which blocks Ito and IK repolarizing potassium channels, would increase organization of epicardial electrograms during ventricular fibrillation while it lowered defibrillation energy requirements. METHODS We measured magnitude-squared coherence, a measure of spatial organization, and ventricular fibrillation (VF) cycle length, ventricular effective refractory period (VERP), and monophasic action potential duration (APD90) as well as defibrillation energy threshold (E50) at baseline and after 150 micrograms/kg of tedisamil (n = 13) or saline control (n = 6) in an open chest dog model. RESULTS After tedisamil, mean magnitude-squared coherence increased by 132 +/- 133%, from 0.15 +/- 0.08 to 0.31 +/- 0.16 (P < 0.001); VF cycle length increased from 121 +/- 24 to 190 +/- 63 ms (P < 0.001) and became more regular, with the coefficient of variation between adjacent VF intervals decreasing from 14.1 +/- 6.9 to 3.9 +/- 2.2% (P < 0.001). Mean E50 decreased from 8.9 +/- 3.8 to 6.1 +/- 2.7 joules (P < 0.001); VERP increased from 158 +/- 30 to 201 +/- 31 ms (P < 0.001), and APD90 increased from 177 +/- 25 to 244 +/- 45 ms (P < 0.001) after tedisamil. No electrophysiologic parameter was changed after saline infusion. CONCLUSIONS Tedisamil increases both spatial coherence and temporal regularity of ventricular fibrillation. These effects on 'order' during VF may be in part responsible for the observed reduction in defibrillation energy requirements.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hypothesis for low-energy transthoracic defibrillation.

timely and informative. The Belfast group has a prodigious experience in out-of-hospital resuscitation and their prospectively collected data have been invaluable in determining energy requirements for defibrillation. The evidence indicating the need for defibrillators storing more than 400 Ws is, at present, inadequate and unconvincing (Lown et al., 1978). In addition to the views expressed by...

متن کامل

A Prospective, Randomized Study

Background Recent development of a prototype singlelead unipolar transvenous defibrillator offers the possibility of device implantation with the ease of a permanent pacemaker. Lowering defibrillation energy requirements would allow for a further reduction in defibrillator generator size and enhance the feasibility of pacemaker-like placement. However, if achieving a lower defibrillation energy...

متن کامل

Effects of tedisamil (KC-8857) on cardiac electrophysiology and ventricular fibrillation in the rabbit isolated heart.

1. The direct cardiac electrophysiological and antifibrillatory actions of tedisamil (KC-8857) were studied in rabbit isolated hearts. 2. Tedisamil (1, 3, and 10 microM), prolonged the ventricular effective refractory period (VRP) from 120 +/- 18 ms (baseline) to 155 +/- 19, 171 +/- 20, and 205 +/- 14 ms, respectively. Three groups of isolated hearts (n = 6 each) were used to test the antifibri...

متن کامل

Internal cardioversion of atrial fibrillation in sheep.

BACKGROUND The cardioversion efficacy of multiple defibrillation waveforms and electrode systems was compared in a sheep model of atrial fibrillation. METHODS AND RESULTS Sustained atrial fibrillation could be induced with rapid atrial pacing in 23 (55%) of the animals. This study was performed in four parts. Six sheep with sustained atrial fibrillation were used for data analysis for each pa...

متن کامل

A prospective evaluation of two defibrillation safety margin techniques in patients with low defibrillation energy requirements.

INTRODUCTION In patients undergoing defibrillator implantation, an appropriate defibrillation safety margin has been considered to be either 10 J or an energy equal to the defibrillation energy requirement. However, a previous clinical report suggested that a larger safety margin may be required in patients with a low defibrillation energy requirement. Therefore, the purpose of this prospective...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Cardiovascular research

دوره 33 2  شماره 

صفحات  -

تاریخ انتشار 1997