Stability-indicating chromatographic methods for the determination of sertindole.

نویسندگان

  • Nariman A El-Ragehy
  • Nagiba Y Hassan
  • Mohamed Abdelkawy
  • Mahmoud A Tantawy
چکیده

In this work, two chromatographic methods have been developed and validated for the determination of sertindole (an antipsychotic agent) in the presence of its oxidative degradation product. Sertindole was subjected to stress stability studies, including acid, alkali, oxidative, photolytic and thermal degradation. The chromatographic methods included the use of thin-layer chromatography (TLC-densitometry) and high-performance liquid chromatography (HPLC). The TLC method employed aluminum TLC plates precoated with silica gel G.F254 as the stationary phase and methanol-ethyl acetate-33% ammonia (1:9:0.1, by volume) as the mobile phase, and the chromatograms were scanned at 227 nm. The developed HPLC method used a reversed-phase C18 column with isocratic elution. The mobile phase was composed of phosphate buffer pH 3.0-acetonitrile-triethylamine (45:55:0.03, by volume) and run at a flow rate of 1.0 mL/min. Quantitation was achieved with ultraviolet detection at 256 nm. The linearity ranges were found to be 2-14 µg/band and 5-200 µg/mL for TLC and HPLC, respectively. The developed methods were validated according to the International Conference on Harmonization guidelines and were applied for bulk powder and dosage forms.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Stability Indicating HPLC Method for the Determination of Fluvoxamine in Pharmaceutical Dosage Forms

Fluvoxamine maleate is a selective serotonin reuptake inhibitor, which is used for the treatment of different types of depressive disorders. In the present study, a stability indicating HPLC method was developed and validated for the determination of fluvoxamine maleate. The chromatographic separation was carried out using a Nova-Pak CN column and a mixture of K2HPO4 50 mM (pH 7.0) and acetonit...

متن کامل

A Stability Indicating HPLC Method for the Determination of Fluvoxamine in Pharmaceutical Dosage Forms

Fluvoxamine maleate is a selective serotonin reuptake inhibitor, which is used for the treatment of different types of depressive disorders. In the present study, a stability indicating HPLC method was developed and validated for the determination of fluvoxamine maleate. The chromatographic separation was carried out using a Nova-Pak CN column and a mixture of K2HPO4 50 mM (pH 7.0) and acetonit...

متن کامل

A stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation

The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...

متن کامل

A stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation

The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...

متن کامل

IMPROVED CHROMATOGRAPHIC METHOD FOR DETERMINATION OF SODIUM DICLOFENAC IN INJECTABLE SOLUTION AND PREDICTION OF CHEMICAL STABILITY

Two modified methods for assaying sodium diclofenac were developed by GC and HPLC. Diclofenac was converted into methyl ester derivative by methyl iodide in acetone. The ester was extract and subjected to GLC with flame ionization detector. %5 SE-30/chrom W-HP (80-100 mesh) was used as a column in GC. For reversed phase HPLC, the mobile phase was methanol and water (55-45). The separation was p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of chromatographic science

دوره 52 6  شماره 

صفحات  -

تاریخ انتشار 2014