Disappointing short-term results with the DePuy ASR XL metal-on-metal total hip arthroplasty.
نویسندگان
چکیده
Outcomes of ultralarge-diameter femoral heads used in metal-on-metal (MOM) total hip arthroplasty (THA) are relatively unknown. This study reports on early failures of the ASR XL (Depuy, Warsaw, Ind) and assesses whether a correlation with cup positioning exists. A retrospective review of 70 consecutive MOM THAs with ultralarge-diameter femoral head and monoblock acetabular component was conducted. Minimum follow-up was 24 months. Of 70 THAs, 12 (17.1%) required revision within 3 years for pain (7), loosening (3), and squeaking (2). Three additional THAs noted squeaking, 2 noted grinding, and 3 additional hips had persistent pain. In total, 20 (28.6%) of 70 demonstrated implant dysfunction. Acetabular components for all symptomatic hips were in acceptable range of cup abduction and anteversion. The failures noted with this design do not correlate to cup placement. The high rate of implant dysfunction at early follow-up suggests serious concerns with the concept of MOM THA with an ultralarge-diameter femoral head paired with a monoblock acetabular cup.
منابع مشابه
Early failure of articular surface replacement XL total hip arthroplasty.
The ASR (articular surface replacement) XL (DePuy, Warsaw, Ind) metal-on-metal hip arthroplasty offers the advantage of stability and increased motion. However, an alarming number of early failures prompted the evaluation of patients treated with this system. A prospective study of patients who underwent arthroplasty with the ASR XL system was performed. Patients with 2-year follow-up or any re...
متن کاملFive-year results of the ASR XL Acetabular System and the ASR Hip Resurfacing System: an analysis from the Australian Orthopaedic Association National Joint Replacement Registry.
BACKGROUND Articular Surface Replacement (ASR) hip prostheses, which have metal-on-metal bearing surfaces, were manufactured by DePuy Orthopaedics (Warsaw, Indiana) for use in both conventional total hip arthroplasty and hip resurfacing. Both the ASR XL Acetabular System and the ASR Hip Resurfacing System were recently recalled worldwide by the manufacturer. This report summarizes an analysis b...
متن کاملExplant analysis of the Biomet Magnum/ReCap metal-on-metal hip joint
OBJECTIVES The high revision rates of the DePuy Articular Surface Replacement (ASR) and the DePuy ASR XL (the total hip arthroplasty (THA) version) have led to questions over the viability of metal-on-metal (MoM) hip joints. Some designs of MoM hip joint do, however, have reasonable mid-term performance when implanted in appropriate patients. Investigations into the reasons for implant failure ...
متن کاملFemoral diameter and stem type are independent risk factors for ARMD in the Large-headed ASR THR group
BACKGROUND Adverse soft-tissue reaction to metal debris (ARMD) continues to be major source of concern in metal-on-metal (MoM) hip replacements. In our earlier study we were able to establish several risk factors for ARMD in patients who had received a small-diameter (<50 mm) Articular Surface Replacement (ASR, DePuy, Warsaw, IN, USA). The aims of the present study were to analyze whether these...
متن کاملWorse health-related quality of life and hip function in female patients with elevated chromium levels
Background and purpose - Blood metal ion levels can be an indicator for detecting implant failure in metal-on-metal (MoM) hip arthroplasties. Little is known about the effect of bilateral MoM implants on metal ion levels and patient-reported outcomes. We compared unilateral patients and bilateral patients with either an ASR hip resurfacing (HR) or an ASR XL total hip replacement (THR) and inves...