Statistical approach of assessing the reliability of glucose sensors: the GLYCENSIT procedure.
نویسندگان
چکیده
BACKGROUND In healthcare, patients with diabetes are instructed on how to apply intensified insulin therapy in an optimal manner. Tight blood glucose control is also performed on patients treated in the intensive care unit (ICU). Different blood glucose meters and glucose monitoring systems (GMSs) are used to achieve this goal, and some may lack reliability. METHODS The GLYCENSIT procedure is a statistical assessment tool we are proposing for evaluating the significant difference of paired glucose measurements. The performance of the GlucoDay system in the ICU is analyzed with GLYCENSIT. RESULTS THE GLYCENSIT ANALYSIS COMPRISES THREE PHASES: testing possible persistent measurement behavior as a function of the glycemic range, testing the number of measurement errors with respect to a standard criterion for binary assessment of glucose sensors, and computing the tolerance intervals that indicate possible test sensor deviations for new observations. The probability of the tolerance intervals directly reflects the number of samples and additionally improves current assessment techniques. The method can be tuned according to the clinician's preferences regarding significance level, tolerance level, and glycemic range cutoff values. The measurement behavior of the GlucoDay sensor is found to be persistent but inaccurate and returns wide tolerance intervals, suggesting that the GlucoDay sensor may not be sufficiently reliable for glycemia control in the ICU. CONCLUSIONS The GLYCENSIT procedure aims to serve as statistical guide for clinicians in the assessment of glucose sensor devices.
منابع مشابه
Sequential-Based Approach for Estimating the Stress-Strength Reliability Parameter for Exponential Distribution
In this paper, two-stage and purely sequential estimation procedures are considered to construct fixed-width confidence intervals for the reliability parameter under the stress-strength model when the stress and strength are independent exponential random variables with different scale parameters. The exact distribution of the stopping rule under the purely sequential procedure is approximated ...
متن کاملDevelopment of a Design Procedure for Aeronautical Structures Based on Reliability
In this paper, an approach to aeronautical structural design based on reliability analysis is presented. In this way, the concept of level of safety is discussed and methods of its calculation using statistical data are described. Based on the concept of level of safety, a design procedure is proposed. In order to validate this design procedure, two design cases are studied. In the first case s...
متن کاملMulti-Objective Economic-Statistical Design of VSSI-MEWMA-DWL Control Chart with Multiple Assignable Causes
This paper proposes a multi-objective model for the economic-statistical design of the variable sample size and sampling interval multivariate exponentially weighted moving average control chart by using double warning lines. The Markov chain approach is used to obtain the statistical properties. We extend the Lorenzen and Vance cost function considering multiple assignable causes and multivari...
متن کاملGlucose-Sensitive Holographic (Bio)Sensors: Fundamentals and Applications
Nowadays sensors and especially biosensors play an important role in medical diagnosis and detection of food and environment contaminations. Biosensors’ facilities have been improved significantly by using technologies such as surface plasmon resonance, microfluidics, laser, and electrochemistry. These technologies are now available on chips in micro- and nano-scale and are capable of mea...
متن کاملModel-based Approach for Multi-sensor Fault Identification in Power Plant Gas Turbines
In this paper, the multi-sensor fault diagnosis in the exhaust temperature sensors of a V94.2 heavy duty gas turbine is presented. A Laguerre network-based fuzzy modeling approach is presented to predict the output temperature of the gas turbine for sensor fault diagnosis. Due to the nonlinear dynamics of the gas turbine, in these models the Laguerre filter parts are related to the linear d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of diabetes science and technology
دوره 2 6 شماره
صفحات -