Two dimensional mapping of the perfusion of the retina and optic nerve head.

نویسندگان

  • G Michelson
  • B Schmauss
چکیده

AIM To present a new non-invasive method of performing a high definition topography of perfused vessels of the retina and the optic nerve head with simultaneous evaluation of blood flow. METHOD By a combination of a laser Doppler flowmeter with a scanning laser system the perfusion of the retina and the optic nerve head is visualised. The principles of measuring blood flow by laser Doppler flowmetry are based on the optical Doppler effect: laser light scattered by a moving particle is shifted in frequency by an amount delta f. Our data acquisition and evaluation system is a modified laser scanning tomograph. The technical data are retinal area of measurement 2.7 mm x 0.7 mm, 10 degrees field with 256 points x 64 lines, measurement accuracy 10 microns, wavelength 670 nm and 790 nm, light power 100 microW and 200 microW, data acquisition time 2.048 s. Every line is scanned 128 times by a line sampling rate of 4000 Hz. By performing a discrete fast Fourier transformation over 128 intensities of each retinal point the laser Doppler shift is calculated for each retinal point. With these data a two dimensional map with 256 x 64 points of the retinal perfusion is created. The brightness of the pixel is coded by the value of the Doppler shift. Offline capillary blood flow is estimated in arbitrary units according to the theory of laser Doppler flowmetry in every region of interest of the perfusion picture. We estimated the reliability and the validity of the method. Retinal blood flow was measured by scanning laser Doppler flowmetry (SLDF) while varying intraocular pressure by a suction cup of three healthy volunteers. Measurements of retinal blood flow performed in 47 eyes by the presented method (SLDF) were correlated with data gained by a commercially available laser Doppler flowmeter. Perfusion pictures of the superficial retinal layer and of deep prelaminar layers in the optic nerve head are presented. RESULTS The reliability coefficients r1 of 'flow', 'volume', and 'velocity' were 0.84, 0.85, and 0.84 respectively. We found a significant linear relation between SLDF flow and the ocular perfusion pressure (r = 0.84, p < 0.001). Comparative measurements of the retinal blood flow by SLDF and a commercially available laser Doppler flowmeter showed a linear and significant relation (flow r = 0.6, p < 0.0001, volume r = 0.4, p < 0.01). Capillaries of the retinal superficial vasculature or deep ciliary sourced capillaries of the optic nerve head became visible with a high resolution by the confocal technique dependent on the focus. Offline, the blood flow variables of areas of 100 microns x 100 microns were calculated. CONCLUSION SLDF enables the visualisation of perfused capillaries and vessels of the retina and the optic nerve head in high resolution by two dimensional mapping of perfusion variables which are encoded by the Doppler signal. This method achieves simultaneously qualitative and quantitative evaluation of capillary blood flow of distinct areas of the capillary meshwork.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Applications of Optical Coherence Tomography in Ophthalmology

Assessment of the peripapillary nerve fiber layer and macular thickness can be determined in ophthalmology using optical coherence tomography (OCT). Decreased nerve fiber layer thickness and macular ganglion cell thickness in optic nerve ischemia have been correlated with visual field loss. OCT allows deep optic nerve head evaluation which helps understand pathophysiology of diseases.  Furtherm...

متن کامل

Diagnostic Value of Color Doppler Imaging and Pattern Visual Evoked Potential in Primary Open-Angle Glaucoma

The vascular aetiology of glaucoma hypothesizes that a compromised blood supply to the optic nerve head contributes to optic nerve head damage. Localized damage may occur when ocular perfusion deficits of the optic nerve head, the retina, the choroid or the retrobulbar vessels falls outside the normal range of autoregulation. This may be the result of systemic dysfunction (vasosclerosis, small ...

متن کامل

Solar Retinopathy Following Methamphetamine Abuse

Purpose: To report a case of solar retinopathy following methamphetamine (MA) abuse. Case report: A 37-years-old man was visited with sudden painless loss of vision in both eyes. He was addicted to methamphetamine for three years. He used MA at the day of admission. Excessive sun gazing (4 hours) took place due to using hallucinations secondary to the MA. Visual acuity was 15/400 Snellen chart ...

متن کامل

Three Dimensional Ultrasonography of the Eye and Measurement of Optical Nerve Sheet Diameter in Dog

Objective-  To determine the possibility of three-dimensional ultrasonography (3DUS) and measurement of optical nerve sheet by this method. Design- Descriptive study. Animals- 10 mixed normal dogs (5males, 5 females), age 1-1.5 year, and weighting 15±5 kg Procedure- 3D ultrasounds of the eyes were evaluated and the normal optical nerves in 3DUS images were measured using Volouson 730 pro....

متن کامل

P129: Use of Stem Cells to Regenerate Degenerative Optic Nerve

Stem cells are undifferentiated cells that have the ability to convert to different types of cells and after dividing, they can produce their own cells or other cells. Axons of the retinal ganglion cells, from the optic nerve. These cells lose the ability to regenerate themselves before birth. Optic nerve degeneration can result from various causes including increased intraocular pressure, comp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 79 12  شماره 

صفحات  -

تاریخ انتشار 1995