Validation of the femoral anteversion measurement method used in imageless navigation
نویسندگان
چکیده
Total hip arthroplasty restores lost mobility to patients suffering from osteoarthritis and acute trauma. In recent years, navigated surgery has been used to control prosthetic component placement. Furthermore, there has been increasing research on what constitutes correct placement. This has resulted in the definition of a safe-zone for acetabular cup orientation. However, there is less definition with regard to femoral anteversion and how it should be measured. This study assesses the validity of the femoral anteversion measurement method used in imageless navigation, with particular attention to how the neutral rotation of the femur is defined. CT and gait analysis methodologies are used to validate the reference which defines this neutral rotation, i.e., the ankle epicondyle piriformis (AEP) plane. The findings of this study indicate that the posterior condylar axis is a reliable reference for defining the neutral rotation of the femur. In imageless navigation, when these landmarks are not accessible, the AEP plane provides a useful surrogate to the condylar axis, providing a reliable baseline for femoral anteversion measurement.
منابع مشابه
Validation of a computer navigation system and a CT method for determination of the orientation of implanted acetabular cup in total hip arthroplasty: a cadaver study.
BACKGROUND Successful hip reconstruction to restore the normal hip biomechanics requires precise placement of implants. Computer assisted navigation in total hip arthroplasty has been proposed to have the potential to help achieve a high accuracy in implant placement. The goal of the study was to evaluate the accuracy of an imageless computer navigation system on cadavers and to validate a non-...
متن کاملAccuracy of acetabular cup positioning using imageless navigation
BACKGROUND Correct placement of the acetabular cup is a crucial step in total hip replacement to achieve a satisfactory result and remains a challenge with free-hand techniques. Imageless navigation may provide a viable alternative to free-hand technique and improve placement significantly. The purpose of this project was to assess and validate intra-operative placement values for both inclinat...
متن کاملIntraoperative validation of navigated limb measurements in THA using a pinless femoral array.
Appropriate limb length (LL) and femoral offset (OS) after total hip arthroplasty (THA) are crucial for a successful and lasting outcome. However, intraoperative assessment is difficult. Computed navigation is effective but the use of radiation and of invasive bone references is cause of concern. Imageless, pinless navigation systems have been shown to be accurate in experimental studies. Howev...
متن کاملDevelopment of imageless computer navigation for acetabular component position in total hip replacement.
The purpose of this study was to develop an imageless (without preoperative computerized tomography (CT) scans or intraoperative fluoroscopy) computer navigation system for total hip replacement. One-hundred and ninety-five hips were operated with imageless computer navigation. Eighty-five hips were operated prior to obtaining precise results, with precision refined in the subsequent 110 hips. ...
متن کاملInitial Results of an Acetabular Center Axis Registration Technique in Navigated Hip Arthroplasty with Deformed Acetabular Rims
BACKGROUND In cementless total hip arthroplasty, imageless computer-assisted navigation is usually used to register the anterior pelvic plane (APP). The accuracy of this method is influenced by the subcutaneous tissues overlying the registration landmarks. On the other hand, the acetabular center axis (ACA) is determined from the acetabular rim. Precise registration of the ACA is possible becau...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 17 شماره
صفحات -
تاریخ انتشار 2012