Blind estimation of the arterial input function in dynamic contrast-enhanced MRI using purity maximization.

نویسندگان

  • Yu-Chun Lin
  • Tsung-Han Chan
  • Chong-Yung Chi
  • Shu-Hang Ng
  • Hao-Li Liu
  • Kuo-Chen Wei
  • Yau-Yau Wai
  • Chun-Chieh Wang
  • Jiun-Jie Wang
چکیده

Uncertainty in arterial input function (AIF) estimation is one of the major errors in the quantification of dynamic contrast-enhanced MRI. A blind source separation algorithm was proposed to determine the AIF by selecting the voxel time course with maximum purity, which represents a minimal contamination from partial volume effects. Simulations were performed to assess the partial volume effect on the purity of AIF, the estimation accuracy of the AIF, and the influence of purity on the derived kinetic parameters. In vivo data were acquired from six patients with hypopharyngeal cancer and eight rats with brain tumor. Results showed that in simulation the AIF with the highest purity is closest to the true AIF. In patients, the manually selection had reduced purity, which could lead to underestimations of K(trans) and V(e) and an overestimation of V(p) when compared with those obtained by the proposed blind source separation algorithm. The derived kinetic parameters in the tumor were more susceptible to the changes in purity when compared with those in the muscle. The animal experiment demonstrated good reproducibility in blind source separation-AIF derived parameters. In conclusion, the blind source separation method is feasible and reproducible to identify the voxel with the tracer concentration time course closest to the true AIF.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Efficient Framework for Accurate Arterial Input Selection in DSC-MRI of Glioma Brain Tumors

Introduction: Automatic arterial input function (AIF) selection has an essential role in quantification of cerebral perfusion parameters. The purpose of this study is to develop an optimal automatic method for AIF determination in dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) of glioma brain tumors by using a new preprocessing method.Material and Methods: For this study, ...

متن کامل

Effect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies

Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...

متن کامل

Automatic Prostate Cancer Segmentation Using Kinetic Analysis in Dynamic Contrast-Enhanced MRI

Background: Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) provides functional information on the microcirculation in tissues by analyzing the enhancement kinetics which can be used as biomarkers for prostate lesions detection and characterization.Objective: The purpose of this study is to investigate spatiotemporal patterns of tumors by extracting semi-quantitative as well as w...

متن کامل

A new constrained blind estimation algorithm for determination of the arterial input function without reference tissues

Introduction: A major challenge in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is the need to provide a measured estimate of the arterial input function (AIF) in order to perform pharmacokinetic modeling analysis of the resulting data. Measurement of the AIF requires the presence of a major artery in the imaging field-of-view, a significantly faster sampling rate than for tis...

متن کامل

Characteristics and reproducibility of the arterial input function (AIF) derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) studies and its effect on renal functional parameters

Purpose: The aim of this study was to investigate parameters of the aortic input function (AIF) in dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) of the kidney and its effect on renal functional parameters (perfusion and glomerular filtration rate) calculated using a two-compartment model analysis. Inter-observer agreement, effect of size of region of interest (ROI) in the aor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 68 5  شماره 

صفحات  -

تاریخ انتشار 2012