Biomechanical evaluation of a novel dualplate fixation method for proximal humeral fractures without medial support

نویسندگان

  • Yu He
  • Yaoshen Zhang
  • Yan Wang
  • Dongsheng Zhou
  • Fu Wang
چکیده

BACKGROUND Comminuted fractures of the proximal humerus are generally treated with the locking plate system, and clinical results are satisfactory. However, unstable support of the medial column results in varus malunion and screw perforation. We designed a novel medial anatomical locking plate (MLP) to directly support the medial column. Theoretically, the combined application of locking plate and MLP (LPMP) would directly provide strong dual-column stability. We hypothesized that the LPMP could provide greater construct stability than the locking plate alone (LP), locking plate combined with a fibular graft (LPSG), and locking plate combined with a distal radius plate (LPDP). METHODS LP, LPMP, LPSG, and LPDP implants were instrumented into the finite element model of a proximal humeral fracture. Axial, shear, and rotational loads were applied to the models under normal and osteoporotic bone conditions. The whole simulation was repeated five times for each fixator. To assess the biomechanical characteristics, the construct stiffness, fracture micromotion, stress distribution, and neck-shaft angle (NSA) were compared. RESULTS The LPMP group showed significantly greater integral and regional construct stiffness, and endured less von Mises stresses, than the other three fixation methods. The stresses on the lateral locking plate were dispersed by the MLP. The LPMP group showed the least change in NSA. CONCLUSIONS From the finite element viewpoint, the LPMP method provided both lateral and medial direct support. The LPMP system was effective in treating proximal humeral fracture with an unstable medial column.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of Additional Medial Plate in Treatment of Proximal Humeral Fractures With Unstable Medial Column

The purpose of this study was to use finite element analysis to compare the biomechanical characteristics after lateral locking plate (LLP) or LLP with a medial anatomical locking plate (LLP-MLP) fixation of proximal humeral fractures with an unstable medial column.First, a 3-dimensional, finite element analysis model was developed. Next, LLP and LLP-MLP implants were instrumented into the prox...

متن کامل

Locking plate fixation with and without inferomedial screws for proximal humeral fractures: a biomechanical study.

PURPOSE. To compare the efficacy of locking plate fixation with and without inferomedial screws in maintaining the reduction of a proximal humeral fracture. METHODS. 22 synthetic humerus models were used. A standardised 3-part proximal humeral fracture with a 4-mm wedge segment was created and fixed with a locking plate and screws with (n=11) and without (n=11) inferomedial screws. The intrafra...

متن کامل

The Mechanical Benefit of Medial Support Screws in Locking Plating of Proximal Humerus Fractures

BACKGROUND The purpose of this study was to evaluate the biomechanical advantages of medial support screws (MSSs) in the locking proximal humeral plate for treating proximal humerus fractures. METHODS Thirty synthetic left humeri were randomly divided into 3 subgroups to establish two-part surgical neck fracture models of proximal humerus. All fractures were fixed with a locking proximal hume...

متن کامل

Fixation of a Proximal Humeral Fracture Using a Novel Intramedullary Cage Construct following a Failed Conservative Treatment

A majority of proximal humeral fractures are preferably treated conservatively. However, surgical management may be beneficial in proximal humeral fractures with significant displacement or angulation. Unfortunately, the complication rates associated with current surgical procedures for fracture fixation, ORIF and IM devices, can be unacceptably high. A new technology, termed the PH Cage, addre...

متن کامل

Proximal humeral nonunion treated with an intramedullary tantalum cylinder.

Nonunion is uncommon after proximal humerus fracture surgery. There is no agreement about preferred method of treatment. Traditional approaches have included laterally based locking plates, autogenous grafting, and endosteal support to provide improved biomechanical stability. Open reduction and internal fixation (ORIF) of proximal humeral nonunion has been performed with various methods, inclu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017