Compact microwave cavity for high performance rubidium frequency standards.
نویسندگان
چکیده
The design, realization, and characterization of a compact magnetron-type microwave cavity operating with a TE(011)-like mode are presented. The resonator works at the rubidium hyperfine ground-state frequency (i.e., 6.835 GHz) by accommodating a glass cell of 25 mm diameter containing rubidium vapor. Its design analysis demonstrates the limitation of the loop-gap resonator lumped model when targeting such a large cell, thus numerical optimization was done to obtain the required performances. Microwave characterization of the realized prototype confirmed the expected working behavior. Double-resonance and Zeeman spectroscopy performed with this cavity indicated an excellent microwave magnetic field homogeneity: the performance validation of the cavity was done by achieving an excellent short-term clock stability as low as 2.4 × 10(-13) τ(-1/2). The achieved experimental results and the compact design make this resonator suitable for applications in portable atomic high-performance frequency standards for both terrestrial and space applications.
منابع مشابه
Frequency stabilization of a frequency-doubled 1556-nm source to the 5S(1/2) ? 5D (5/2) two-photon transitions of rubidium.
Improvements in the power level of sources near 1550 nm and in the efficiency of waveguide frequency doublers enabled us to lock a frequency-doubled source directly to the 5S(1/2) ? 5D(5/2) two-photon transitions near 778 nm. We obtained a sufficiently powerful second-harmonic signal, exceeding 2 mW, by doubling an external-cavity diode laser that was amplified by an erbium-doped fiber amplifie...
متن کاملDouble-resonance spectroscopy in Rubidium vapour-cells for high performance and miniature atomic clocks
We report our studies on using microwave-optical double-resonance (DR) spectroscopy for a high-performance Rb vapour-cell atomic clock in view of future industrial applications. The clock physics package is very compact with a total volume of only 0.8 dm. It contains a recently in-house developed magnetron-type cavity and a Rb vapour cell. A homedmade frequency-stabilized laser system with an i...
متن کاملLaser-Pumped Rubidium Frequency Standards: New Analysis and Progress - Quantum Electronics, IEEE Journal of
We have achieved a stability of 3 10 13 1=2 for 3 < < 30 s with a laser-pumped rubidium gas-cell frequency standard by reducing the effects due to noise in the microwave and laser sources. This result is one order of magnitude better than the best present performance of lamp-pumped devices.
متن کاملCompact High-Performance Continuous-Wave Double-Resonance Rubidium Standard With 1.4 × 10−13 tau −1/2 Stability
We present our studies on a compact high-performance continuous wave (CW) double-resonance (DR) rubidium frequency standard in view of future portable applications. Our clock exhibits a short-term stability of 1.4 × 10−13 τ −1/2, consistent with the short-term noise budget for an optimized DR signal. The metrological studies on the mediumto longterm stability of our Rb standard with measured st...
متن کاملLow-noise, high resolution microwave synthesis for atomic frequency standards
The performance of newer generations of ultra high stability atomic frequency standards based on laser cooled atoms and ions appears to be limited by the local oscillator and the microwave synthesis chain. To improve this performance, the design considerations of microwave synthesizers for Cs hyperfine clock transition at 9.192 GHz that emphasize high resolution, low phase modulation (PM) and a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Review of scientific instruments
دوره 83 10 شماره
صفحات -