Correction to Optical and Electrochemical Methods for Determining the Effective Area and Charge Density of Conducting Polymer Modified Electrodes for Neural Stimulation.
نویسندگان
چکیده
Neural stimulation is used in the cochlear implant, bionic eye, and deep brain stimulation, which involves implantation of an array of electrodes into a patient's brain. The current passed through the electrodes is used to provide sensory queues or reduce symptoms associated with movement disorders and increasingly for psychological and pain therapies. Poor control of electrode properties can lead to suboptimal performance; however, there are currently no standard methods to assess them, including the electrode area and charge density. Here we demonstrate optical and electrochemical methods for measuring these electrode properties and show the charge density is dependent on electrode geometry. This technique highlights that materials can have widely different charge densities but also large variation in performance. Measurement of charge density from an electroactive area may result in new materials and electrode geometries that improve patient outcomes and reduce side effects.
منابع مشابه
STRUCTURAL AND IONIC CONDUCTIVITYSTUDIES ONPLASTICIZED PAN-SODIUM FLUORIDE POLYMER ELECTROLYTES FOR ELECTROCHEMICAL CELL APPLICATIONS
Ion conducting gel polymer electrolytes based on poly acrylonitrle (PAN) complexed with different weight percent ratios of Sodium Fluoride (NaF) salt were prepared by using solution cast technique. Structural characterization was performed using X-ray diffraction (XRD) technique and Fourier transforms infrared (FTIR) spectroscope technique. From the X-rd results increase in amorphous phase with...
متن کاملFabrication of a Selective and Sensitive Electrochemical Sensor Modified with Magnetic Molecularly Imprinted Polymer for Amoxicillin
A modified electrochemical sensor for the determination of amoxicillin (AMX) was reported in this paper. The magnetic molecularly imprinted polymer (MMIP) were suspended in AMX solution and then collected on the surface of a magnetic carbon paste electrode (CPE) via a permanent magnet, situated within the carbon paste electrode and then the voltammetry signals were recorded. It was confirmed th...
متن کاملAn investigation on effect of backbone geometric anisotropy on the performance of infiltrated SOFC electrodes
Design of optimal microstructures for infiltrated solid oxide fuel cell (SOFC) electrodes is a complicated process because of the multitude of the electrochemical and physical phenomena taking place in the electrodes in different temperatures, current densities and reactant flow rates. In this study, a stochastic geometric modeling method is used to create a range of digitally realized infi...
متن کاملAn aptasensor based on electrosynthesized conducting polymers, Cu2O–carbon dots and biosynthesized gold nanoparticles, for monitoring carcinoembryonic antigen
Current work proposes an inimitable composite, with great electrical conductivity and quite enhanced surface area, (including conducting polymers (poly (cathechol)), Cu2O–carbon dots and green synthesized gold nanoparticles) for detecting acute carcinoembryonic antigen. At current work, the electropolymerization was offered instead of enzyme-catalyzed polymerization of poly (catechol). <b...
متن کاملFlexible Electrode Array for Retinal Stimulation
In this Work, ITO/PET (Indium Tin Oxide / Polyethylene Terephthalate) electrode structure which provides biocompatibility, mechanical stability and flexibility is fabricated. Flexible ITO/PET implantable electrode array for a retina has been developed. The electrode array is fabricated on a thin PET/ITO substrate and is encapsulated using, SU-8, an insulating material. PET substrate and SU-8 po...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical chemistry
دوره 87 1 شماره
صفحات -