Early lung cancer detection using spiral computed tomography and positron emission tomography.

نویسندگان

  • Gorka Bastarrika
  • María José García-Velloso
  • Maria Dolores Lozano
  • Usua Montes
  • Wenceslao Torre
  • Natalia Spiteri
  • Arantza Campo
  • Luis Seijo
  • Ana Belén Alcaide
  • Jesús Pueyo
  • David Cano
  • Isabel Vivas
  • Octavio Cosín
  • Pablo Domínguez
  • Patricia Serra
  • José A Richter
  • Luis Montuenga
  • Javier J Zulueta
چکیده

RATIONALE Lung cancer screening using computed tomography (CT) is effective in detecting lung cancer in early stages. Concerns regarding false-positive rates and unnecessary invasive procedures have been raised. OBJECTIVE To study the efficiency of a lung cancer protocol using spiral CT and F-18-fluorodeoxyglucose positron emission tomography (FDG-PET). METHODS High-risk individuals underwent screening with annual spiral CTs. Follow-up CTs were done for noncalcified nodules of 5 mm or greater, and FDG-PET was done for nodules 10 mm or larger or smaller (> 7 mm), growing nodules. RESULTS A total of 911 individuals completed a baseline CT study and 424 had at least one annual follow-up study. Of the former, 14% had noncalcified nodules of 5 mm or larger, and 3.6% had nodules of 10 mm or larger. Eleven non-small cell lung cancers (NSCLC) and one small cell lung cancer (SCLC) were diagnosed in the baseline study (prevalence rate, 1.32%), and two NSCLCs in the annual study (incidence rate, 0.47%). All NSCLCs (92% of prevalence cancers) were diagnosed in stage I (12 stage IA, 1 stage IB). FDG-PET was helpful for the correct diagnosis in 19 of 25 indeterminate nodules. The sensitivity, specificity, positive predictive value, and negative predictive value of FDG-PET for the diagnosis of malignancy were 69, 91, 90, and 71%, respectively. However, the sensitivity and negative predictive value of the screening algorithm, which included a 3-month follow-up CT for nodules with a negative FDG-PET, was 100%. CONCLUSION A protocol for early lung cancer detection using spiral CT and FDG-PET is useful and may minimize unnecessary invasive procedures for benign lesions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of Alzheimer\\\\\\\'s Disease using Multitracer Positron Emission Tomography Imaging

Alzheimer's disease is characterized by impaired glucose metabolism and demonstration of amyloid plaques. Individual positron emission tomography tracers may reveal specific signs of pathology that is not readily apparent on inspection of another one. Combination of multitracer positron emission tomography imaging  yields promising results. In this paper, 57 Alzheimer's disease neuroimaging ini...

متن کامل

Respiratory motion correction in prostate cancer positron emission tomography: A study on patients and phantom simulation

Introduction: To investigate the effects of breathing cycle and tree diaphragm motions on prostate cancer tumors standard uptake value (SUV) during positron emission tomography (PET) and to correct it. Materials and methods: Respiratory motion traces were simulated on the common patient breathing cycle and tree diaphragm motio...

متن کامل

[Diagnosis and Treatment for Multiple Primary Lung Cancer].

Multiple primary lung cancer (MPLC) is an uncommon entity of the primary lung cancer. With the widespread use of early detection tools such as multislice spiral computed tomography (CT), positron emission tomography (PET), and the better survival results after resection of primary lung cancer, more and more MPLC have been detected. However, the current diagnostic and therapeutic methods cannot ...

متن کامل

Early lung-cancer detection with spiral CT and positron emission tomography in heavy smokers: 2-year results.

BACKGROUND Low-dose spiral CT of the chest effectively detects early-stage lung cancer in high-risk individuals. The high rate of benign nodules and issues of making a differential diagnosis are critical factors that currently hamper introduction of large-scale screening programmes. We investigated the efficacy of repeated yearly spiral CT and selective use of positron emission tomography (PET)...

متن کامل

Pulmonary tuberculosis with false-positive 18F-fluorodeoxyglucose positron emission tomography mimicking recurrent lung cancer: A case report

Recurrent lung cancer is a common clinical condition. 18F-fluorodeoxyglucose positron emission tomography (FDG-PET) is currently the predominant non-invasive imaging technique used for the detection of tumor recurrence. In the present study, the case of a 67-year-old male suspected to have postoperative recurrence of primary lung cancer was examined. Chest computed tomography (CT) scans identif...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • American journal of respiratory and critical care medicine

دوره 171 12  شماره 

صفحات  -

تاریخ انتشار 2005